From 36cffd63d7976f89de72c2c8e0efd19e50dc33da Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Mateusz=20Gruszczy=C5=84ski?= Date: Wed, 23 Sep 2026 09:43:42 +0200 Subject: [PATCH] GREE Controller 0.15.19 --- custom_components/gree_controller/manifest.json | 2 +- gree-controller/CHANGELOG.md | 6 ++++++ gree-controller/README.md | 2 +- gree-controller/config.yaml | 2 +- 4 files changed, 9 insertions(+), 3 deletions(-) diff --git a/custom_components/gree_controller/manifest.json b/custom_components/gree_controller/manifest.json index 213a75e..de35e07 100644 --- a/custom_components/gree_controller/manifest.json +++ b/custom_components/gree_controller/manifest.json @@ -1,7 +1,7 @@ { "domain": "gree_controller", "name": "GREE Controller", - "version": "0.15.18", + "version": "0.15.19", "config_flow": true, "integration_type": "hub", "iot_class": "local_polling", diff --git a/gree-controller/CHANGELOG.md b/gree-controller/CHANGELOG.md index 0f355fa..f365d2f 100644 --- a/gree-controller/CHANGELOG.md +++ b/gree-controller/CHANGELOG.md @@ -1,5 +1,11 @@ # Changelog +## 0.15.19 + +- Fixes Visual Flow `zone_thermostat` OFF semantics: `power=false` now powers the assigned unit off without setting the persistent Zone `enabled` flag to false. +- Keeps the Zone available for subsequent Flow/schedule evaluation after an OFF action while preserving the existing explicit physical OFF command and ownership checks. +- Preserves backward-compatible `power=true` recovery of Zones left disabled by older Flow executions. + ## 0.15.18 - Persists the evaluated Flow trigger trace whenever a Flow-generated automation executes or reaches a failed execution attempt, so the trigger context reflects the values from that exact moment instead of current live readings. diff --git a/gree-controller/README.md b/gree-controller/README.md index d453a02..8d48340 100644 --- a/gree-controller/README.md +++ b/gree-controller/README.md @@ -2,7 +2,7 @@ Local GREE HVAC controller packaged as a Home Assistant add-on, with Web UI, HTTP/WebSocket API, built-in Swagger API documentation, UDP discovery/control, `amd64` and `aarch64` support, ingress, and database backup from `/data/gree-controller.db`. -Version 0.15.18 records the exact Flow condition trace at execution time and shows the evaluated Flow variables and gates directly under Recently triggered automations in Control plan. +Version 0.15.19 fixes Flow thermostat OFF semantics: `zone_thermostat power=false` powers the assigned unit off without disabling the Zone, so Flow and thermostat evaluation remain active. ![Home Assistant OS + GREE + VLAN topology](https://git.linuxiarz.pl/gru/gree-controller-ha-addon/raw/branch/master/gree-controller/topology-ha-vlan-gree-en.png) diff --git a/gree-controller/config.yaml b/gree-controller/config.yaml index 7d83dcd..6e3742d 100644 --- a/gree-controller/config.yaml +++ b/gree-controller/config.yaml @@ -1,5 +1,5 @@ name: "GREE Controller" -version: "0.15.18" +version: "0.15.19" slug: "gree_controller" description: "Local GREE HVAC controller with Web UI, API, and Home Assistant integration" url: "https://git.linuxiarz.pl/gru/gree-controller-ha-addon/"