v0.13.8
This commit is contained in:
+4
-3
@@ -1,6 +1,6 @@
|
||||
# GREE Controller API reference
|
||||
|
||||
HTTP and WebSocket API for GREE Controller **0.13.7**.
|
||||
HTTP and WebSocket API for GREE Controller **0.13.8**.
|
||||
|
||||
[← Main documentation](../README.md)
|
||||
|
||||
@@ -48,6 +48,7 @@ GET /
|
||||
GET /index.html
|
||||
GET /app.js
|
||||
GET /theme-init.js
|
||||
GET /lang-init.js
|
||||
GET /styles.css
|
||||
GET /manifest.webmanifest
|
||||
GET /sw.js
|
||||
@@ -231,7 +232,7 @@ Response:
|
||||
{
|
||||
"status": "ok",
|
||||
"name": "gree-controller",
|
||||
"version": "0.13.7",
|
||||
"version": "0.13.8",
|
||||
"uptime_seconds": 1234,
|
||||
"control_ready": true,
|
||||
"time": "2026-08-30T06:54:00Z"
|
||||
@@ -294,7 +295,7 @@ Returns the initial Web UI snapshot:
|
||||
"control_plan": {"generated_at": "2026-09-04T08:00:00Z", "zones": [], "rules": []},
|
||||
"control_plan_revision": 42,
|
||||
"system": {
|
||||
"version": "0.13.7",
|
||||
"version": "0.13.8",
|
||||
"uptime_seconds": 1234,
|
||||
"auth_required": false,
|
||||
"control_ready": true,
|
||||
|
||||
+3
-3
@@ -2,9 +2,9 @@
|
||||
"openapi": "3.1.0",
|
||||
"info": {
|
||||
"title": "GREE Controller API",
|
||||
"version": "0.13.7",
|
||||
"version": "0.13.8",
|
||||
"summary": "Local HTTP/WebSocket API for GREE HVAC control",
|
||||
"description": "Self-hosted API used by the GREE Controller Web UI and Home Assistant integration.\n\n### Authentication\nNormal administrator endpoints accept `Authorization: Bearer <APP_TOKEN>` or `x-api-token: <APP_TOKEN>` when `GREE_CONTROLLER_APP_TOKEN` is configured. If the app token is empty, those endpoints intentionally run in trusted-LAN mode without authentication.\n\nThe restricted `/api/integrations/home-assistant/*` control surface always requires either a generated access token or the administrator app token. Generated tokens do **not** grant normal administrator API access.\n\nIn Swagger UI use **Authorize** and enter the token in either the bearer field or `x-api-token` field.\n\n### Control ownership\nThermostat zones, groups, house rules, direct device control, schedules and visual Flows share an ownership/arbitration model. Prefer zone/group/house endpoints for thermostat intent; direct device commands are technical/manual control and can deliberately take ownership.\n\n### 0.12.0 breaking API\nRuntime settings are split into functional `/api/settings/*` resources. The former `/api/settings`, `/api/debug`, `/api/events/retention`, `/api/settings/export` and `/api/settings/import` endpoints were removed without compatibility aliases.\n\n### 0.13.0\n`control-plan` keeps its existing HTTP response shape but is materialized in memory and pushed to WebSocket clients as `control_plan.updated`; HTTP remains the fallback/resync path. A restricted Home Assistant snapshot endpoint combines devices, groups and the control plan.\n\n### 0.13.1\nRuntime WebSocket churn is reduced without changing contracts: no-op zone regulator heartbeats are deduplicated and device heartbeat polls only invalidate the materialized control plan when plan-relevant device state changes.\n\n### 0.13.2\nCompletes live WebSocket synchronization for entity creation, schedules, automations, configuration imports and runtime device/automation state while preserving the existing HTTP API contracts and control-plan fallback behavior.\n\n### 0.13.3\nLogical thermostat targets are normalized to 0.1 C consistently, including Temporary Quick Thermostat and thermostat-managed automation/Flow actions. The bundled Web UI accepts comma or dot decimal input for the temporary thermostat target; physical GREE setpoint rounding is unchanged.\n\n### 0.13.4\nDisabled-zone thermostat controls remain visually active in the bundled Web UI because explicit temporary/manual thermostat and direct manual control remain available while zone automation is disabled. HTTP and WebSocket contracts are unchanged.\n\n### 0.13.5\nThe zone settings dialog now explains directly beside the enabled/disabled option that disabling a zone stops automation but does not block manual thermostat, temporary thermostat or direct manual control. HTTP and WebSocket contracts remain unchanged.\n\n### 0.13.6\nNotification settings add a dedicated sensor_discrepancy alert type for GREE vs Home Assistant room-temperature divergence. Disabling it suppresses only that notification; the GREE safety fallback remains active.\n\n### 0.13.7\nThe bootstrap snapshot now embeds all eight redacted runtime settings views. The bundled Web UI consumes those settings directly for HTTP startup and WebSocket resynchronization, removing the previous settings-request fan-out while preserving the split settings endpoints for direct reads and writes.",
|
||||
"description": "Self-hosted API used by the GREE Controller Web UI and Home Assistant integration.\n\n### Authentication\nNormal administrator endpoints accept `Authorization: Bearer <APP_TOKEN>` or `x-api-token: <APP_TOKEN>` when `GREE_CONTROLLER_APP_TOKEN` is configured. If the app token is empty, those endpoints intentionally run in trusted-LAN mode without authentication.\n\nThe restricted `/api/integrations/home-assistant/*` control surface always requires either a generated access token or the administrator app token. Generated tokens do **not** grant normal administrator API access.\n\nIn Swagger UI use **Authorize** and enter the token in either the bearer field or `x-api-token` field.\n\n### Control ownership\nThermostat zones, groups, house rules, direct device control, schedules and visual Flows share an ownership/arbitration model. Prefer zone/group/house endpoints for thermostat intent; direct device commands are technical/manual control and can deliberately take ownership.\n\n### 0.12.0 breaking API\nRuntime settings are split into functional `/api/settings/*` resources. The former `/api/settings`, `/api/debug`, `/api/events/retention`, `/api/settings/export` and `/api/settings/import` endpoints were removed without compatibility aliases.\n\n### 0.13.0\n`control-plan` keeps its existing HTTP response shape but is materialized in memory and pushed to WebSocket clients as `control_plan.updated`; HTTP remains the fallback/resync path. A restricted Home Assistant snapshot endpoint combines devices, groups and the control plan.\n\n### 0.13.1\nRuntime WebSocket churn is reduced without changing contracts: no-op zone regulator heartbeats are deduplicated and device heartbeat polls only invalidate the materialized control plan when plan-relevant device state changes.\n\n### 0.13.2\nCompletes live WebSocket synchronization for entity creation, schedules, automations, configuration imports and runtime device/automation state while preserving the existing HTTP API contracts and control-plan fallback behavior.\n\n### 0.13.3\nLogical thermostat targets are normalized to 0.1 C consistently, including Temporary Quick Thermostat and thermostat-managed automation/Flow actions. The bundled Web UI accepts comma or dot decimal input for the temporary thermostat target; physical GREE setpoint rounding is unchanged.\n\n### 0.13.4\nDisabled-zone thermostat controls remain visually active in the bundled Web UI because explicit temporary/manual thermostat and direct manual control remain available while zone automation is disabled. HTTP and WebSocket contracts are unchanged.\n\n### 0.13.5\nThe zone settings dialog now explains directly beside the enabled/disabled option that disabling a zone stops automation but does not block manual thermostat, temporary thermostat or direct manual control. HTTP and WebSocket contracts remain unchanged.\n\n### 0.13.6\nNotification settings add a dedicated sensor_discrepancy alert type for GREE vs Home Assistant room-temperature divergence. Disabling it suppresses only that notification; the GREE safety fallback remains active.\n\n### 0.13.7\nThe bootstrap snapshot now embeds all eight redacted runtime settings views. The bundled Web UI consumes those settings directly for HTTP startup and WebSocket resynchronization, removing the previous settings-request fan-out while preserving the split settings endpoints for direct reads and writes.\n\n### 0.13.8\nThe bundled Web UI suppresses the initial English-to-selected-language flash with a dedicated pre-paint language initializer and reveals the application only after localization is initialized. Language-pack URLs are content-versioned so immutable browser caching stays safe across updates.",
|
||||
"license": {
|
||||
"name": "MIT"
|
||||
}
|
||||
@@ -4891,7 +4891,7 @@
|
||||
},
|
||||
"version": {
|
||||
"type": "string",
|
||||
"example": "0.13.7"
|
||||
"example": "0.13.8"
|
||||
},
|
||||
"uptime_seconds": {
|
||||
"type": "integer",
|
||||
|
||||
Reference in New Issue
Block a user