This commit is contained in:
Mateusz Gruszczyński
2026-09-16 14:24:40 +02:00
parent d0ae3d0f6a
commit 3f9acb1675
28 changed files with 726 additions and 127 deletions
+163 -7
View File
@@ -2,9 +2,9 @@
"openapi": "3.1.0",
"info": {
"title": "GREE Controller API",
"version": "0.14.12",
"version": "0.14.13",
"summary": "Local HTTP/WebSocket API for GREE HVAC control",
"description": "Self-hosted API used by the GREE Controller Web UI and Home Assistant integration.\n\n### Authentication\nAdministrator endpoints accept `Authorization: Bearer <APP_TOKEN>` or `x-api-token: <APP_TOKEN>` when configured. Restricted Home Assistant control endpoints also accept generated integration tokens.\n\n### Local and GREE Cloud\nDevices use one API model and one command surface. `connection_type=local` is dispatched only to the existing LAN/UDP provider; `connection_type=gree_cloud` is dispatched only to the GREE Cloud provider. No automatic transport fallback is performed.\n\n### GREE Cloud security\nCloud passwords, REST/MQTT tokens, Authorization values and device cipher keys are never returned in normal API responses or Cloud diagnostics. MQTT uses TLS with certificate and hostname validation.\n\n### Energy\nGREE Cloud `ElcAll` and selected Home Assistant cumulative energy sensors are normalized to kWh and converted to consumption deltas before aggregation. Raw cumulative values are retained only as meter samples/baselines.\n\n### 0.14.12\nThe Home Assistant add-on now uses the Supervisor Core API proxy and runtime SUPERVISOR_TOKEN automatically; standalone Home Assistant URL/token configuration is unchanged.\n\n### 0.14.11\nWeb UI icons now use a shared inline SVG set instead of font-dependent Unicode glyphs across navigation, dialogs, Flow, charts, controls and event categories for consistent cross-platform rendering.\n\n\n### 0.14.10\nNight mode and Home Assistant / Sensors standalone settings now use the full available page width, matching the other Web UI sections.\n\n### 0.14.9\nPower controls use an embedded SVG icon instead of a font-dependent Unicode glyph. Home Assistant room-sensor stale/error events identify the affected entity and zone, and historical event rows can recover that context from metadata.\n\n### 0.14.8\nRemaining Home Assistant and notification diagnostic errors no longer use device-transport 502 responses. Missing/invalid integration configuration returns 400, configured external dependency failures return 424, and 502 is reserved for Local/LAN GREE device communication.\n\n### 0.14.7\nHome Assistant energy-sensor discovery now returns an empty optional result when HA is not configured, uses 424 for configured external-dependency failures, and custom select popovers use their rendered height when positioning above a field.\n\n\n### 0.14.6\nFixes dynamic custom-select duplication in History → Energy and hides Energy history controls when no energy source is configured.\n\n### 0.14.5\nWeb UI single-choice controls now use one consistent custom dropdown, language packs are loaded on demand, and the dashboard outdoor temperature opens a 24-hour history modal.\n\n### 0.14.4\nHome Assistant connection tests validate only the configured server/API token and require no entity. `outdoor_entity_id` is the global Home Assistant outdoor-temperature sensor; zones can override it with `ha_outdoor_entity_id`. Room-temperature Home Assistant sensors remain configured per zone with `ha_entity_id`. Global/per-zone outdoor sensors are integrated with aliases, metrics/history and Visual Flow entity suggestions.\n\n### 0.14.2\nAdds independent vertical/horizontal swing controls across manual device control, thermostat zones, legacy automations, Visual Flow and Home Assistant zone climates. Swing is treated as an auxiliary one-shot unit setting and does not replace thermostat ownership.\n\n### 0.14.1\nAdds split/multisplit installation groups with shared energy and outdoor-temperature sources, multi-target energy charts with period comparison, cleaner Cloud status/alerts and safe MQTT cleanup after the last Cloud device is removed.\n\n### 0.14.0\nAdds first-class GREE Cloud MQTT status/control, reconnect/resubscribe lifecycle, Cloud diagnostics, per-device capabilities, Cloud/HA energy sources and energy-history aggregation while preserving the LAN transport contract.",
"description": "Self-hosted API used by the GREE Controller Web UI and Home Assistant integration.\n\n### Authentication\nAdministrator endpoints accept `Authorization: Bearer <APP_TOKEN>` or `x-api-token: <APP_TOKEN>` when configured. Restricted Home Assistant control endpoints also accept generated integration tokens.\n\n### Local and GREE Cloud\nDevices use one API model and one command surface. `connection_type=local` is dispatched only to the existing LAN/UDP provider; `connection_type=gree_cloud` is dispatched only to the GREE Cloud provider. No automatic transport fallback is performed.\n\n### GREE Cloud security\nCloud passwords, REST/MQTT tokens, Authorization values and device cipher keys are never returned in normal API responses or Cloud diagnostics. MQTT uses TLS with certificate and hostname validation.\n\n### Energy\nGREE Cloud `ElcAll` and selected Home Assistant cumulative energy sensors are normalized to kWh and converted to consumption deltas before aggregation. Raw cumulative values are retained only as meter samples/baselines.\n\n### 0.14.13\nHome Assistant add-on authentication is now hidden behind an automatic Supervisor status, manual URL/token fallback is unlocked only after a failed HA test, connection tests return a live sample entity reading, and Shared Flow input HA sources include searchable live entity suggestions.\n\n### 0.14.12\nThe Home Assistant add-on now uses the Supervisor Core API proxy and runtime SUPERVISOR_TOKEN automatically; standalone Home Assistant URL/token configuration is unchanged.\n\n### 0.14.11\nWeb UI icons now use a shared inline SVG set instead of font-dependent Unicode glyphs across navigation, dialogs, Flow, charts, controls and event categories for consistent cross-platform rendering.\n\n\n### 0.14.10\nNight mode and Home Assistant / Sensors standalone settings now use the full available page width, matching the other Web UI sections.\n\n### 0.14.9\nPower controls use an embedded SVG icon instead of a font-dependent Unicode glyph. Home Assistant room-sensor stale/error events identify the affected entity and zone, and historical event rows can recover that context from metadata.\n\n### 0.14.8\nRemaining Home Assistant and notification diagnostic errors no longer use device-transport 502 responses. Missing/invalid integration configuration returns 400, configured external dependency failures return 424, and 502 is reserved for Local/LAN GREE device communication.\n\n### 0.14.7\nHome Assistant energy-sensor discovery now returns an empty optional result when HA is not configured, uses 424 for configured external-dependency failures, and custom select popovers use their rendered height when positioning above a field.\n\n\n### 0.14.6\nFixes dynamic custom-select duplication in History → Energy and hides Energy history controls when no energy source is configured.\n\n### 0.14.5\nWeb UI single-choice controls now use one consistent custom dropdown, language packs are loaded on demand, and the dashboard outdoor temperature opens a 24-hour history modal.\n\n### 0.14.4\nHome Assistant connection tests validate only the configured server/API token and require no entity. `outdoor_entity_id` is the global Home Assistant outdoor-temperature sensor; zones can override it with `ha_outdoor_entity_id`. Room-temperature Home Assistant sensors remain configured per zone with `ha_entity_id`. Global/per-zone outdoor sensors are integrated with aliases, metrics/history and Visual Flow entity suggestions.\n\n### 0.14.2\nAdds independent vertical/horizontal swing controls across manual device control, thermostat zones, legacy automations, Visual Flow and Home Assistant zone climates. Swing is treated as an auxiliary one-shot unit setting and does not replace thermostat ownership.\n\n### 0.14.1\nAdds split/multisplit installation groups with shared energy and outdoor-temperature sources, multi-target energy charts with period comparison, cleaner Cloud status/alerts and safe MQTT cleanup after the last Cloud device is removed.\n\n### 0.14.0\nAdds first-class GREE Cloud MQTT status/control, reconnect/resubscribe lifecycle, Cloud diagnostics, per-device capabilities, Cloud/HA energy sources and energy-history aggregation while preserving the LAN transport contract.",
"license": {
"name": "MIT"
}
@@ -3095,7 +3095,7 @@
"Diagnostics"
],
"summary": "Test Home Assistant connection",
"description": "Validates the configured Home Assistant URL and access token against the Home Assistant API root. No entity is required or read.",
"description": "Validates the active Home Assistant authentication path and state registry. In the add-on this uses Supervisor auth unless manual fallback is active. A successful response includes one readable entity sample when available.",
"operationId": "testHomeAssistant",
"security": [
{
@@ -3115,15 +3115,58 @@
"properties": {
"ok": {
"type": "boolean"
},
"auth_mode": {
"type": "string",
"enum": [
"manual",
"supervisor"
]
},
"sample": {
"type": [
"object",
"null"
],
"properties": {
"entity_id": {
"type": "string"
},
"name": {
"type": "string"
},
"state": {
"type": "string"
},
"unit": {
"type": "string"
}
},
"required": [
"entity_id",
"name",
"state",
"unit"
],
"additionalProperties": false
}
},
"required": [
"ok"
"ok",
"auth_mode",
"sample"
],
"additionalProperties": false
},
"example": {
"ok": true
"ok": true,
"auth_mode": "supervisor",
"sample": {
"entity_id": "sensor.living_room_temperature",
"name": "Living room temperature",
"state": "22.4",
"unit": "°C"
}
}
}
}
@@ -5465,6 +5508,89 @@
}
}
}
},
"/api/integrations/home-assistant/entities": {
"get": {
"tags": [
"Diagnostics"
],
"summary": "List Home Assistant entities for UI suggestions",
"description": "Returns a compact, authenticated Home Assistant state-registry view used by searchable entity pickers in Shared Flow input configuration.",
"operationId": "listHomeAssistantEntities",
"security": [
{
"BearerToken": []
},
{
"ApiTokenHeader": []
}
],
"responses": {
"200": {
"description": "Entity suggestion catalog",
"content": {
"application/json": {
"schema": {
"type": "object",
"properties": {
"configured": {
"type": "boolean"
},
"entities": {
"type": "array",
"items": {
"type": "object",
"properties": {
"entity_id": {
"type": "string"
},
"name": {
"type": "string"
},
"state": {
"type": "string"
},
"unit": {
"type": "string"
},
"device_class": {
"type": "string"
}
},
"required": [
"entity_id",
"name",
"state",
"unit",
"device_class"
],
"additionalProperties": false
}
}
},
"required": [
"configured",
"entities"
],
"additionalProperties": false
}
}
}
},
"400": {
"$ref": "#/components/responses/BadRequest"
},
"401": {
"$ref": "#/components/responses/Unauthorized"
},
"424": {
"$ref": "#/components/responses/FailedDependency"
},
"500": {
"$ref": "#/components/responses/InternalError"
}
}
}
}
},
"components": {
@@ -5520,7 +5646,7 @@
},
"version": {
"type": "string",
"example": "0.14.12"
"example": "0.14.13"
},
"uptime_seconds": {
"type": "integer",
@@ -8520,6 +8646,10 @@
"url": {
"type": "string"
},
"manual_url": {
"type": "string",
"description": "Persisted manual Home Assistant URL used only when manual fallback is active in the add-on; equals url in standalone mode."
},
"auth_mode": {
"type": "string",
"enum": [
@@ -8556,6 +8686,22 @@
},
"token_configured": {
"type": "boolean"
},
"manual_token_configured": {
"type": "boolean",
"description": "Whether a persisted manual Home Assistant token is available for fallback."
},
"supervisor_detected": {
"type": "boolean",
"description": "True when the packaged Home Assistant add-on environment was detected."
},
"supervisor_token_detected": {
"type": "boolean",
"description": "True when the add-on environment exposes a non-empty SUPERVISOR_TOKEN."
},
"manual_auth_override": {
"type": "boolean",
"description": "True when the add-on is explicitly using the persisted manual URL/token fallback."
}
},
"required": [
@@ -8567,7 +8713,12 @@
"sensor_aliases",
"flow_inputs",
"outdoor_assist_enabled",
"token_configured"
"token_configured",
"manual_url",
"manual_token_configured",
"supervisor_detected",
"supervisor_token_detected",
"manual_auth_override"
],
"additionalProperties": false
},
@@ -8609,6 +8760,11 @@
"null"
],
"description": "Omit/null to preserve the stored token; empty string clears it."
},
"manual_auth_override": {
"type": "boolean",
"default": false,
"description": "In the Home Assistant add-on only, switch from automatic Supervisor auth to the persisted manual URL/token fallback. Ignored for standalone behavior."
}
},
"required": [