@@ -75,7 +75,7 @@ During normal heating/cooling the controller minimizes unit power cycling. It ke
- when the zone requires conditioning, use the active target (optionally assisted slightly by outdoor weather),
- when the zone is satisfied, move the device setpoint to the non-demand side of the room target so the inverter/compressor can stop naturally,
- use hysteresis and a minimum adjustment interval to avoid command chatter,
- optionally adjust fan speed based on room error and outdoor extremes.
- optionally adjust fan speed based on room error and outdoor extremes; with Smart fan enabled, a satisfied zone uses Low fan together with the standby setpoint and requests Quiet mode in the same frame when the unit supports it. Unsupported Quiet commands automatically fall back to Low fan without breaking thermostat control.
Each zone has separate seasonal profile temperatures: