@@ -53,11 +53,11 @@ The Flow editor exposes:
- Flow-scoped execution/dry-run logs,
- import/export of versioned `.flow.json` source graphs.
Dry-run never mutates thermostats, devices, groups, schedules or automations. For an existing Flow it clones persisted stateful runtime data, so timers and rolling/oscillation windows are evaluated against the same saved state without writing it back.
Dry-run never mutates thermostats, devices, groups, schedules or automations. For an existing Flow it clones persisted stateful runtime data, so timers, last-observed values, rate-limit history and rolling/oscillation windows are evaluated against the same saved state without writing it back.
## Blocks
Condition/source blocks include weekday, time range, date range, optional 5-field CRON triggers, application Night mode, outdoor/device/zone temperature, house mode, device state, thermostat/zone state, group state, Home Assistant state/numeric/attribute/availability, rolling mean/median windows, numeric oscillation detection, a diagnostic constant, and `shared_input`. Stateful `stable_for`, `delay`, rolling statistics and oscillation blocks persist runtime state in the generated automation payload so restarts do not silently reset timing or history. Editing a stateful block resets only that block's incompatible runtime state. Shared inputs are configured centrally in Home Assistant / Sensors and referenced by ID. Shared inputs store reusable value sources only; operators and comparison values are configured exclusively in each Flow reference. Logic blocks are AND, OR and NOT.
Condition/source blocks include weekday, time range, date range, optional 5-field CRON triggers, application Night mode, outdoor/device/zone temperature, house mode, device state, thermostat/zone state, group state, Home Assistant state/numeric/attribute/availability, rolling mean/median windows, numeric oscillation detection, a diagnostic constant, and `shared_input`. Stateful gates include `stable_for`, bounded `state_duration`, `on_change` (condition-result or raw-value edge), `rate_limit` (maximum successful executions in a rolling period), and `delay`. Their runtime state, together with rolling statistics and oscillation samples, is persisted in the generated automation payload so restarts do not silently reset timing/history. Editing a stateful block resets only that block's incompatible runtime state. Flow state continues to be observed while the action itself is in cooldown, preventing stale continuity/change state. A `rate_limit` block must be placed directly before an action and consumes quota only after a successful execution; suppressed or failed actions do not consume it. Shared inputs are configured centrally in Home Assistant / Sensors and referenced by ID. Shared inputs store reusable value sources only; operators and comparison values are configured exclusively in each Flow reference. Logic blocks are AND, OR and NOT.
Actions include thermostat zone, GREE device, climate group, and generic Home Assistant service calls (`domain`, `service`, optional `entity_id`, JSON service data). Direct GREE actions expose power, HVAC mode, target temperature, fan speed, vertical/horizontal swing, quiet, turbo, light, air, xfan, health and sleep.
@@ -73,13 +73,12 @@ The canvas supports multi-selection (Shift/Ctrl/Cmd), `Ctrl/Cmd+A`, Select all /
## Good next stateful blocks
Stateful timing now has persisted runtime support for `stable_for`, delay-before-action, rolling mean/median samples and oscillation detection. Useful next additions on the same runtime-state foundation are:
Stateful timing now has persisted runtime support for `stable_for`, bounded state duration, change detection, rolling execution limits, delay-before-action, rolling mean/median samples and oscillation detection. Useful next additions on the same runtime-state foundation are:
- debounce,
- hysteresis block,
- rising/falling edge,
- cooldown/rate limit independent of the action,
- retry/backoff,
- debounce with configurable dead time,
- a dedicated external-entity thermostat/hysteresis action (rather than duplicating the built-in HVAC thermostat),
- explicit rising/falling edge modes,
- retry/backoff for external service failures,
- variables/counters,
- reusable subflows/macros,
- explicit priority/mutex groups for actions,