v0.7.12-hotfix
This commit is contained in:
+2
-2
@@ -137,11 +137,11 @@ curl -X POST "$BASE/api/zones/ZONE_ID/control" -H "$AUTH" -H 'Content-Type: appl
|
||||
|
||||
`mode` on the quick zone endpoint accepts `house`, `cool`, or `heat`. `house` means **Follow global mode** in the UI and should be left unchanged when the zone is meant to inherit the global GREE Controller mode. A fixed `cool`/`heat` is an explicit per-zone override; therefore house mode `off` stops inherited zones but does not disable a zone deliberately fixed to Cooling or Heating. Whole-house master power remains authoritative over all zones.
|
||||
|
||||
`power:true/false` on `/api/zones/{id}/control` is a local quick-thermostat power override, not a physical/manual command. `true` lets that zone run through the full thermostat even when its climate group is off and cancels any pending local hand-back timer. `false` turns only that zone off immediately and sets `local_thermostat_resume_at` to 15 minutes in the future. When that deadline is reached, the controller clears local quick ownership plus its temporary quick preset/setpoint and recalculates the current group/schedule/house-mode state instead of restoring an old physical ON/OFF snapshot. `clear_local_thermostat_override:true` performs that hand-back immediately. Direct/pilot-style control remains `/api/devices/{id}/command`.
|
||||
`power:true/false` on `/api/zones/{id}/control` is a local quick-thermostat power override, not a physical/manual command. `true` lets that zone run through the full thermostat even when its climate group is off and cancels any pending local hand-back timer. Every accepted `false` action turns only that zone off immediately and creates a fresh backend-owned `local_thermostat_resume_at` 15 minutes in the future. When that deadline is reached, the controller clears local quick ownership plus its temporary quick preset/setpoint and recalculates the current group/schedule/house-mode state instead of restoring an old physical ON/OFF snapshot. `clear_local_thermostat_override:true` performs that hand-back immediately. Direct/pilot-style control remains `/api/devices/{id}/command`.
|
||||
|
||||
### Physical/manual device takeover
|
||||
|
||||
The poller compares climate-relevant unit state with the last controller-known state. An external change of power, HVAC mode, target temperature or fan speed (for example from the IR remote) sets `device_manual_override=true` on the assigned zone. Controller-originated thermostat/group commands are correlated with a short-lived expected-state record when GREE status has not settled yet, so their delayed status transition is not mistaken for an external takeover. The zone continues sensor/history updates but thermostat modulation, schedules, groups and direct-device automations stop issuing corrective climate commands. The controller stores the pre-takeover climate state; if the user later returns the unit to that operational state, the takeover is cleared automatically and the stale **Resume automation** prompt disappears. When the pre-takeover state was OFF, switching the unit OFF again is sufficient even if the remote kept a different dormant target/mode internally. Otherwise the override expires at the next schedule transition when one exists; without a future transition it stays active until explicitly resumed. The known GREE standby normalization from Low fan back to Auto is ignored so it does not create a false takeover.
|
||||
The poller compares climate-relevant unit state with the last controller-known state. An external change of power, HVAC mode, target temperature or fan speed (for example from the IR remote) sets `device_manual_override=true` on the assigned zone. Controller-originated thermostat/group commands are correlated with a short-lived expected-state record when GREE status has not settled yet, so their delayed status transition is not mistaken for an external takeover. The zone continues sensor/history updates but thermostat modulation, schedules, groups and direct-device automations stop issuing corrective climate commands. The controller stores the pre-takeover climate state; if the user later returns the unit to that operational state, the takeover is cleared automatically and the stale **Resume automation** prompt disappears. When the pre-takeover state was OFF, switching the unit OFF again is sufficient even if the remote kept a different dormant target/mode internally. If that OFF state belongs to an active local quick-thermostat hand-back, its countdown is suspended while direct/manual takeover is active and is re-armed for a fresh 15 minutes when the unit returns to OFF. Otherwise the manual-device override expires at the next schedule transition when one exists; without a future transition it stays active until explicitly resumed. The known GREE standby normalization from Low fan back to Auto is ignored so it does not create a false takeover.
|
||||
|
||||
The technical `POST /api/devices/{id}/command` path uses the same takeover semantics for climate-relevant changes; light-only and unrelated feature changes do not suspend the thermostat. Local quick-thermostat power is deliberately separate from this state. An explicit quick-zone action (local power, target, mode, preset or enabled state) resumes thermostat ownership from a physical/direct takeover automatically. It can also be resumed directly:
|
||||
|
||||
|
||||