@@ -14,7 +14,7 @@ Flow is an authoring/orchestration layer. It does not replace the thermostat, sc
## Existing control domains remain authoritative
- `zone_thermostat` writes the existing persistent Zone intent and wakes the normal thermostat cycle. `power=false` sends an explicit physical OFF to the assigned unit but does **not** change the persistent Zone `enabled` flag; Zone enable/disable remains an administrative control gate. It can also issue one-shot granular vertical/horizontal louver commands to the assigned unit; these auxiliary fields do not take over thermostat ownership.
- `zone_thermostat` writes the existing persistent Zone intent and wakes the normal thermostat cycle. `power=false` sends an explicit physical OFF to the assigned unit but does **not** change the persistent Zone `enabled` flag; Zone enable/disable remains an administrative control gate. A concrete Flow mode (`heat`/`cool`) is also written with the OFF frame so a stale device `dry`/`fan` mode is not retained; Flow `auto` remains an ownership policy and is never mapped to physical GREE Auto on OFF. While a zone is owned by `automation.flow`, the global outdoor-assist bias is suppressed so the Flow's own room-temperature thresholds remain authoritative. It can also issue one-shot granular vertical/horizontal louver commands to the assigned unit; these auxiliary fields do not take over thermostat ownership.
- `group_action` calls the existing `control_group` path, including custom group targets.
- `device_action` uses the existing `DeviceCommand` / automatic-device path.
- `device_feature_action` uses the same path but compiles exactly one selected `DeviceCommand` field, leaving all other unit settings untouched.