v0.9.7
This commit is contained in:
+98
-2
@@ -512,7 +512,7 @@
|
||||
"night.description": "Configure quieter thermostat behavior for sleeping hours without mixing it with application settings.",
|
||||
"night.saveHint": "Save night-mode changes.",
|
||||
"homeAssistant.eyebrow": "Integration",
|
||||
"homeAssistant.description": "Connection, temperature sensors, friendly aliases and access tokens for the Home Assistant integration.",
|
||||
"homeAssistant.description": "Home Assistant connection, thermostat temperature sources, shared Flow inputs, sensor aliases and integration access.",
|
||||
"homeAssistant.saveHint": "Save Home Assistant and sensor changes.",
|
||||
"notifications.title": "Notifications",
|
||||
"notifications.hint": "Send important events or only problems/anomalies.",
|
||||
@@ -942,6 +942,102 @@
|
||||
"flow.available": "available",
|
||||
"flow.haAvailableHint": "This condition is true only when the Home Assistant entity returns a state other than unknown/unavailable. Connection errors fail closed as false. Useful as a guard before NOT and safety logic.",
|
||||
"flow.deviceOptions": "Advanced GREE options",
|
||||
"flow.deviceOptionsHint": "These fields use the existing DeviceCommand. Fan/quiet/sleep and dry/fan HVAC modes are blocked on a thermostat-assigned device when they would fight the regulator; use the Thermostat action there instead."
|
||||
"flow.deviceOptionsHint": "These fields use the existing DeviceCommand. Fan/quiet/sleep and dry/fan HVAC modes are blocked on a thermostat-assigned device when they would fight the regulator; use the Thermostat action there instead.",
|
||||
"settings.haConnection": "Home Assistant connection",
|
||||
"settings.haConnectionHint": "Server address and credentials used by all Home Assistant features.",
|
||||
"settings.haThermostatSources": "Thermostat temperature sources",
|
||||
"settings.haThermostatSourcesHint": "These settings belong to thermostat and temperature-source logic, not reusable Flow inputs.",
|
||||
"flow.listEyebrow": "Your automations",
|
||||
"flow.listTitle": "Flow list",
|
||||
"flow.listCount": "{count} Flows",
|
||||
"flow.quickToggleHint": "Enable or disable the Flow without opening the editor",
|
||||
"flow.quickEnabled": "Flow enabled",
|
||||
"flow.quickDisabled": "Flow disabled",
|
||||
"flow.selectAll": "Select all",
|
||||
"flow.clearSelection": "Clear selection",
|
||||
"flow.selectedCount": "Selected: {count}",
|
||||
"flow.node.sharedInput": "Shared input",
|
||||
"flow.sharedInputMissing": "Shared input missing",
|
||||
"flow.sharedInputTitle": "Shared Flow input",
|
||||
"flow.sharedInputEyebrow": "Reusable data",
|
||||
"flow.sharedInputType": "Source type",
|
||||
"flow.sharedInputAdd": "Add input",
|
||||
"flow.sharedInputsTitle": "Shared Flow inputs",
|
||||
"flow.sharedInputsHint": "Define constants, states and sensors once, then reuse them in many Flows. Changes here apply to every Flow that references the input.",
|
||||
"flow.sharedInputsEmpty": "No shared inputs",
|
||||
"flow.sharedInputsEmptyHint": "Add a constant, Home Assistant state, or another shared source for multiple Flows.",
|
||||
"flow.sharedInputNodeHint": "This block uses the central shared-input configuration.",
|
||||
"flow.sharedInputNodeEmptyHint": "Add a shared input in Home Assistant / Sensors first.",
|
||||
"flow.sharedInputNameRequired": "Enter a shared input name.",
|
||||
"flow.sharedInputDeleteConfirm": "Delete shared input “{name}”?",
|
||||
"flow.sharedInputDeleteUsed": "Input “{name}” is used by {count} Flows. Those conditions will evaluate false after deletion. Delete it anyway?",
|
||||
"flow.templateCategory.comfort": "Comfort",
|
||||
"flow.templateCategory.comfort.hint": "Everyday comfort scenarios based on time, weather and house mode.",
|
||||
"flow.templateCategory.energy": "Energy & cost",
|
||||
"flow.templateCategory.energy.hint": "Reduce consumption during absence, expensive energy periods or high household load.",
|
||||
"flow.templateCategory.safety": "Protection & safety",
|
||||
"flow.templateCategory.safety.hint": "Guards for frost, overheating, humidity and open-window operation.",
|
||||
"flow.templateCategory.night": "Night",
|
||||
"flow.templateCategory.night.hint": "Quieter operation, sleep profiles and bedroom conditions.",
|
||||
"flow.templateCategory.reliability": "Reliability",
|
||||
"flow.templateCategory.reliability.hint": "Flows resilient to unavailable sensors, offline devices and disabled thermostats.",
|
||||
"flow.templateCategory.advanced": "Advanced",
|
||||
"flow.templateCategory.advanced.hint": "Nested AND/OR/NOT logic, multiple rooms and Home Assistant states.",
|
||||
"flow.template.morning_boost.title": "Cold-weather morning boost",
|
||||
"flow.template.morning_boost.description": "On workday mornings, only in heating mode and during cold weather, raises the target to 22.5°C.",
|
||||
"flow.template.weekend_comfort.title": "Weekend comfort",
|
||||
"flow.template.weekend_comfort.description": "Keeps daytime comfort on Saturday and Sunday while the house climate mode is not off.",
|
||||
"flow.template.energy_price_eco.title": "Expensive energy + nobody home",
|
||||
"flow.template.energy_price_eco.description": "When energy is expensive and nobody is home, switches the selected zone to an economical away profile.",
|
||||
"flow.template.peak_power_guard.title": "Peak power guard",
|
||||
"flow.template.peak_power_guard.description": "Turns HVAC off when household power draw exceeds the configured threshold while climate control is active.",
|
||||
"flow.template.mild_weather_eco.title": "Mild weather — HVAC off",
|
||||
"flow.template.mild_weather_eco.description": "When outdoor temperature is within a comfortable band and the window is closed, turns HVAC off.",
|
||||
"flow.template.unoccupied_shutdown.title": "Shut down while away",
|
||||
"flow.template.unoccupied_shutdown.description": "During daytime hours, turns off a group or zone when the selected person is away.",
|
||||
"flow.template.humidity_guard.title": "High humidity cooling",
|
||||
"flow.template.humidity_guard.description": "With high humidity, occupancy and cooling house mode, applies moderate cooling.",
|
||||
"flow.template.overheat_guard.title": "Overheat guard",
|
||||
"flow.template.overheat_guard.description": "If a zone is very warm, house mode is cooling and the window is closed, starts protective cooling.",
|
||||
"flow.template.window_available_guard.title": "Window availability + open state",
|
||||
"flow.template.window_available_guard.description": "Turns HVAC off only when the window sensor is available and reports open, avoiding false reactions to unavailable.",
|
||||
"flow.template.sleep_temperature_guard.title": "Night cooling only when needed",
|
||||
"flow.template.sleep_temperature_guard.description": "In night mode, cools only when room temperature is above the threshold and the house is in cooling mode.",
|
||||
"flow.template.bedroom_window_night.title": "Bedroom: night + closed window",
|
||||
"flow.template.bedroom_window_night.description": "Combines night mode with NOT open-window logic so the sleep profile runs only with a closed window.",
|
||||
"flow.template.sensor_availability_guard.title": "Cooling with sensor validation",
|
||||
"flow.template.sensor_availability_guard.description": "Checks HA sensor availability first, then temperature and house mode before starting cooling.",
|
||||
"flow.template.offline_safe_off.title": "Offline device safe-off",
|
||||
"flow.template.offline_safe_off.description": "When a device is offline while its thermostat remains active, issues a conservative off command with a long cooldown.",
|
||||
"flow.template.thermostat_enabled_guard.title": "Control only an active thermostat",
|
||||
"flow.template.thermostat_enabled_guard.description": "Requires an enabled zone, active demand and a non-off house mode before the action executes.",
|
||||
"flow.template.occupancy_weather_matrix.title": "Occupancy + weather + window",
|
||||
"flow.template.occupancy_weather_matrix.description": "Comfort runs only when someone is home, outdoor or room demand exists, and the window is not open.",
|
||||
"flow.template.dual_threshold_control.title": "Dual threshold heating/cooling",
|
||||
"flow.template.dual_threshold_control.description": "Two independent branches heat below the lower threshold and cool above the upper threshold.",
|
||||
"flow.template.multi_room_group_guard.title": "Multiple rooms → one group",
|
||||
"flow.template.multi_room_group_guard.description": "If either of two zones is too warm and house mode is cooling, starts a shared group or zone.",
|
||||
"flow.template.ha_attribute_mode_guard.title": "HA attribute + window + availability",
|
||||
"flow.template.ha_attribute_mode_guard.description": "Reads hvac_action, entity availability and window state to stop HVAC only when the data is trustworthy.",
|
||||
"flow.templateCategory.home_assistant": "Home Assistant / heat sources",
|
||||
"flow.templateCategory.home_assistant.hint": "Coordinate GREE with a gas boiler, external heat source, heating demand and temperatures read from Home Assistant.",
|
||||
"flow.template.ha_gas_heating_off.title": "Gas boiler heating → turn GREE off",
|
||||
"flow.template.ha_gas_heating_off.description": "Reads hvac_action from climate.gas_boiler. When HA reports heating and the entity is available, the selected GREE zone is turned off.",
|
||||
"flow.template.ha_gas_heating_boost.title": "Gas boiler heating → GREE heat boost",
|
||||
"flow.template.ha_gas_heating_boost.description": "When the gas boiler is actively heating, the room is below 20°C and house mode is heat, GREE assists with a 23.5°C target.",
|
||||
"flow.template.ha_gas_heating_reduce.title": "Boiler heating + room warm → reduce GREE",
|
||||
"flow.template.ha_gas_heating_reduce.description": "When gas heat is already active and the zone reaches at least 21°C, lowers the GREE target to 18°C so the heat sources do not fight each other.",
|
||||
"flow.template.ha_gas_backup_heat.title": "Gas not heating + room cold → GREE backup",
|
||||
"flow.template.ha_gas_backup_heat.description": "When the boiler entity is available but does not report heating and the room drops below 19°C, GREE provides backup heat to 22°C.",
|
||||
"flow.template.ha_external_heat_source_off.title": "Other heat source ON → turn GREE off",
|
||||
"flow.template.ha_external_heat_source_off.description": "Generic fireplace, furnace or other source preset. binary_sensor.external_heat_source = on turns the GREE group or zone off.",
|
||||
"flow.template.ha_external_heat_source_assist.title": "Other heat source ON → assist with GREE",
|
||||
"flow.template.ha_external_heat_source_assist.description": "When an external heat source is running but the room is still below 20°C, GREE assists in heat mode with a 23°C target.",
|
||||
"flow.template.ha_heating_demand_follow.title": "Follow Home Assistant heating demand",
|
||||
"flow.template.ha_heating_demand_follow.description": "binary_sensor.heating_demand = on starts GREE heating to 22.5°C while the house is in heat mode.",
|
||||
"flow.template.ha_boiler_supply_boost.title": "Hot boiler supply + cold room → boost",
|
||||
"flow.template.ha_boiler_supply_boost.description": "Reads sensor.boiler_supply_temperature. Above 45°C with a cold room, GREE is set to 23.5°C.",
|
||||
"flow.template.ha_thermostat_idle_fallback.title": "Gas thermostat idle → GREE fallback heat",
|
||||
"flow.template.ha_thermostat_idle_fallback.description": "If climate.gas_boiler is available, reports hvac_action=idle and the room falls below 19°C, GREE heats to 21.5°C."
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user