v0.16.4
This commit is contained in:
1 parent
05185a94f7
commit
bb5caa769f
28 files changed
+592
-130
No files matched your search
@@ -1,7 +1,7 @@
|
||||
{
|
||||
"domain": "gree_controller",
|
||||
"name": "GREE Controller",
|
||||
"version": "0.16.3",
|
||||
"version": "0.16.4",
|
||||
"config_flow": true,
|
||||
"integration_type": "hub",
|
||||
"iot_class": "local_polling",
|
||||
|
||||
@@ -1,5 +1,16 @@
|
||||
# Changelog
|
||||
|
||||
## 0.16.4
|
||||
|
||||
- Fixes a race in stateful Flow checkpoint saving: no stale condition evaluation can re-enable, overwrite or resurrect a disabled/deleted/recompiled automation.
|
||||
- Requires both the generated automation/schedule and its parent Flow to be enabled before participating in the engine, control plan, next-event timeline or API enabled status, including mismatched imported/legacy data.
|
||||
- Adds a second enable/revision check under the execution lock immediately before sending an action. No newly initiated Flow actions after disabling it.
|
||||
- Releases orphaned thermostat intent and pending compressor tasks when a Flow is disabled, deleted, or its action is removed; preserves real manual ownership and avoids retroactively undoing already sent external commands.
|
||||
- Resets Flow timer, change-detection, rolling-window and cooldown state after an OFF → ON transition, so disabled intervals never advance timing conditions.
|
||||
- Filters the dashboard's recent-Flow and simulation cards against the parent state, including the moment between a WebSocket Flow update and a rebuilt control plan.
|
||||
- Adds database and engine regression tests for disabled parents, stale writes, orphaned rules, zone handback and manual takeover.
|
||||
- Restores the three ready-to-import simple heating Flow JSON examples missing from the prior source package and updates the static verification script for the new ownership checker.
|
||||
|
||||
## 0.16.3
|
||||
|
||||
- Adds expandable, per-room examples for nighttime 19/21/23°C modulation, daytime OFF/boost/30-minute stability, zone temperature-source fallback and Flow vs manual ownership.
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
name: "GREE Controller"
|
||||
version: "0.16.3"
|
||||
version: "0.16.4"
|
||||
slug: "gree_controller"
|
||||
description: "Local GREE HVAC controller with Web UI, API, and Home Assistant integration"
|
||||
url: "https://git.linuxiarz.pl/gru/gree-controller-ha-addon/"
|
||||
|
||||
Reference in new issue