@@ -134,8 +134,8 @@ The integration also exposes three controller-level entities on the **GREE Contr
- **Thermostat mode** (`select`) — Cooling, Heating or **Do not control**. Do not control pauses house-level thermostat commands but leaves direct device control and explicit per-zone Heat/Cool overrides untouched.
- **Work profile** (`select`) — Auto schedule, Comfort, Sleep or Away. If zones have mixed manual profiles, the select has no single current option until a whole-house profile is chosen again.
- Choosing **Cooling/Heating** in the thermostat-mode select or any whole-house **Work profile** is treated as explicit whole-house activation: it switches **All air conditioners** back on. **Do not control** does not change master power.
- **All air conditioners** (`switch`) — separate master power. Turning it off powers every enabled unit down and prevents zones/controller automations from restarting them. Turning it on powers all enabled units on again without changing the selected thermostat mode or profile.
- Choosing **Cooling/Heating** changes the house rule for zones that inherit the global mode. **Do not control** pauses only that inherited house rule; explicit local/group/manual control remains independent.
- **All air conditioners** (`switch`) sends one-shot physical ON/OFF commands to all enabled units. It does not enable/disable automation or erase local/group/manual ownership. Its displayed state reflects whether all currently enabled units are physically ON.
These controls use the Home Assistant integration token and the dedicated `/api/integrations/home-assistant/house/*` endpoints.