60 KiB
GREE Controller API reference
HTTP and WebSocket API for GREE Controller 0.14.12.
Base URL and content type
Default local address:
http://127.0.0.1:8787
JSON requests use:
Content-Type: application/json
If GREE_CONTROLLER_BASE_PATH=/gree is configured, every HTTP and WebSocket path below is prefixed with /gree.
Interactive and machine-readable API documentation is served by the application itself:
GET /api-docs Swagger UI
GET /api-docs/openapi.json OpenAPI 3.1 document
The OpenAPI document contains endpoint descriptions, authentication schemes, parameters,
request/response models, examples and common error responses. Its servers entry follows the
configured GREE_CONTROLLER_BASE_PATH, so requests sent from Swagger UI target the current
controller instance correctly.
Authentication
There are three access levels.
Public
No token is required for:
GET /api/health
GET /api-docs
GET /api-docs/openapi.json
GET /
GET /index.html
GET /app.js
GET /theme-init.js
GET /lang-init.js
GET /styles.css
GET /manifest.webmanifest
GET /sw.js
GET /favicon.svg
GET /lang/index.json
GET /lang/{file}
Administrator API
All normal /api/* routes are administrator routes. If GREE_CONTROLLER_APP_TOKEN is empty, the controller intentionally operates in trusted-LAN mode and these routes do not require authentication.
When an app token is configured, send either:
Authorization: Bearer APP_TOKEN
or:
x-api-token: APP_TOKEN
Example:
BASE='http://127.0.0.1:8787'
TOKEN='replace-me'
curl -H "Authorization: Bearer $TOKEN" "$BASE/api/bootstrap"
Restricted Home Assistant API
Generated Home Assistant access tokens always authenticate only the restricted integration surface under /api/integrations/home-assistant/*. The administrator app token is also accepted there.
Generated token secrets are returned only at creation time. SQLite stores their SHA-256 hash and a display prefix.
Errors and HTTP status codes
API errors are JSON:
{
"error": "message"
}
Common statuses:
| Status | Meaning |
|---|---|
200 OK |
Successful read/update/action. |
201 Created |
Resource created. |
204 No Content |
Successful delete/revoke. |
400 Bad Request |
Validation error or unsafe/invalid operation. |
401 Unauthorized |
Missing/incorrect token. |
404 Not Found |
Resource ID does not exist. |
409 Conflict |
Revision/concurrency conflict. |
424 Failed Dependency |
Configured external service/integration (for example Home Assistant, GREE Cloud or a notification provider) could not complete the request. |
502 Bad Gateway |
Local/LAN GREE device communication failure. |
500 Internal Server Error |
Unexpected server/storage error. |
Endpoint index
Public and system
| Method | Endpoint | Description |
|---|---|---|
| GET | /api/health |
Lightweight process/control-engine health. |
| GET | /api/bootstrap |
Complete initial application snapshot. |
| GET | /api/system/info |
Runtime/system diagnostic information. |
| GET | /ws |
Live WebSocket event stream. |
Devices and discovery
| Method | Endpoint | Description |
|---|---|---|
| POST | /api/discovery |
Discover/bind GREE devices. |
| GET | /api/devices |
List devices. |
| POST | /api/devices |
Add a device manually. |
| GET | /api/devices/{id} |
Read a device. |
| PATCH | /api/devices/{id} |
Edit technical device configuration. |
| DELETE | /api/devices/{id} |
Delete a device after safety checks. |
| POST | /api/devices/{id}/bind |
Bind/re-bind a physical unit. |
| POST | /api/devices/{id}/probe |
Minimal non-mutating GREE round-trip diagnostic. |
| POST | /api/devices/{id}/poll |
Poll one unit immediately. |
| POST | /api/devices/{id}/command |
Send a direct/manual device command. |
Thermostat zones, groups and house
| Method | Endpoint | Description |
|---|---|---|
| GET | /api/zones |
List zones. |
| POST | /api/zones |
Create a zone. |
| GET | /api/zones/{id} |
Read a zone. |
| PUT | /api/zones/{id} |
Replace editable zone configuration. |
| DELETE | /api/zones/{id} |
Delete zone after safe device shutdown. |
| POST | /api/zones/{id}/control |
Quick/thermostat control of a zone. |
| POST | /api/zones/{id}/schedule-template |
Replace zone schedules with a built-in template. |
| GET | /api/groups |
List climate groups. |
| POST | /api/groups |
Create a climate group. |
| GET | /api/groups/{id} |
Read a group. |
| PUT | /api/groups/{id} |
Replace group definition. |
| DELETE | /api/groups/{id} |
Delete a group. |
| POST | /api/groups/{id}/control |
Group control enable/mode/preset/custom-temperature control. |
| POST | /api/house/control |
Set global thermostat mode. |
| POST | /api/house/power |
Bulk ON/OFF for all thermostats and enabled units; no persistent global gate. |
| POST | /api/house/preset |
Set/clear whole-house preset override. |
Schedules and automations
| Method | Endpoint | Description |
|---|---|---|
| GET | /api/schedules |
List schedules. |
| POST | /api/schedules |
Create schedule. |
| GET | /api/schedules/{id} |
Read schedule. |
| PUT | /api/schedules/{id} |
Replace schedule. |
| DELETE | /api/schedules/{id} |
Delete schedule. |
| GET | /api/automations |
List automations. |
| POST | /api/automations |
Create automation. |
| GET | /api/automations/{id} |
Read automation. |
| PUT | /api/automations/{id} |
Replace automation. |
| DELETE | /api/automations/{id} |
Delete automation. |
History, control plan and events
| Method | Endpoint | Description |
|---|---|---|
| GET | /api/readings |
Legacy/device reading history. |
| GET | /api/history |
Rich device/zone/HA history. |
| GET | /api/control-plan |
Current resolved thermostat plan. |
| GET | /api/events |
Event/debug log. |
Settings, configuration and diagnostics
| Method | Endpoint | Description |
|---|---|---|
| GET/PUT | /api/settings/application |
Application runtime switches. |
| GET/PUT | /api/settings/gree |
GREE controller, polling, discovery and compressor settings. |
| GET/PUT | /api/settings/history |
Metric/event retention and compaction settings. |
| GET/PUT | /api/settings/influxdb |
InfluxDB history settings. |
| GET/PUT | /api/settings/notifications |
Notification provider and alert settings. |
| GET/PUT | /api/settings/night |
Night mode settings. |
| GET/PUT | /api/settings/home-assistant |
Home Assistant, aliases, shared Flow inputs and outdoor assist. |
| GET/PUT | /api/settings/debug |
Debug overlay/GREE frame settings. |
| GET | /api/configuration/export |
Export full application configuration. |
| POST | /api/configuration/import |
Import/replace application configuration. |
| POST | /api/integrations/home-assistant/test |
Test HA server/API authentication without requiring an entity. |
| POST | /api/integrations/home-assistant/entity |
Read raw HA entity state/attributes for shared Flow input diagnostics. |
| POST | /api/integrations/notifications/test |
Send a test notification. |
Access tokens and restricted Home Assistant API
| Method | Endpoint | Description |
|---|---|---|
| GET | /api/access-tokens |
List generated HA tokens without secrets. |
| POST | /api/access-tokens |
Create restricted HA token. |
| DELETE | /api/access-tokens/{id} |
Revoke token. |
| GET | /api/integrations/home-assistant/snapshot |
Restricted devices + groups + control-plan snapshot in one request. |
| GET | /api/integrations/home-assistant/devices |
Restricted device list. |
| POST | /api/integrations/home-assistant/devices/{id}/command |
Restricted direct device command. |
| GET | /api/integrations/home-assistant/control-plan |
Restricted control plan. |
| GET | /api/integrations/home-assistant/groups |
HA-oriented group state. |
| POST | /api/integrations/home-assistant/groups/{id}/control |
Restricted group control. |
| POST | /api/integrations/home-assistant/house/control |
Restricted house mode. |
| POST | /api/integrations/home-assistant/house/preset |
Restricted house preset. |
| POST | /api/integrations/home-assistant/house/power |
Restricted bulk all-thermostat/all-unit power action. |
| POST | /api/integrations/home-assistant/zones/{id}/control |
Restricted thermostat-zone control. |
System endpoints
GET /api/health
Public lightweight health check.
Response:
{
"status": "ok",
"name": "gree-controller",
"version": "0.14.12",
"uptime_seconds": 1234,
"control_ready": true,
"time": "2026-08-30T06:54:00Z"
}
control_ready=false means the process is running but the thermostat engine has not yet completed its initial physical device synchronization.
GET /api/bootstrap
Returns the initial Web UI snapshot:
{
"devices": [],
"zones": [],
"groups": [],
"schedules": [],
"automations": [],
"flows": [],
"access_tokens": [],
"settings": {
"application": {"simulator_enabled": false},
"gree": {
"controller_id": "gree-controller",
"poll_interval_seconds": 10,
"zone_interval_seconds": 10,
"discovery_timeout_ms": 3000,
"discovery_broadcast": "auto",
"suppress_device_beep": false,
"compressor_protection_enabled": true,
"compressor_protection_seconds": 180
},
"history": {"retention_days": 30, "compaction_enabled": true, "event_retention_days": 30},
"influxdb": {
"enabled": false, "version": "2", "url": "", "database": "gree_controller",
"username": "", "password_configured": false, "org": "", "bucket": "",
"token_configured": false, "history_threshold_days": 30
},
"notifications": {
"enabled": false, "mode": "problems", "provider": "pushover",
"pushover_configured": false, "slack_configured": false, "discord_configured": false,
"cooldown_seconds": 300, "communication_failure_threshold": 3,
"target_timeout_minutes": 60, "alert_types": {}
},
"night": {
"enabled": false, "start_time": "22:00", "end_time": "06:00",
"max_fan_speed": 1, "force_quiet": true, "use_native_sleep": true
},
"home_assistant": {
"url": "", "auth_mode": "manual", "token_configured": false,
"outdoor_entity_id": "", "sensor_stale_after_seconds": 300,
"allow_invalid_tls": false, "sensor_aliases": {}, "flow_inputs": [],
"outdoor_assist_enabled": true
},
"debug": {"overlay_enabled": false, "gree_frames": false}
},
"house": {"mode": "cool"},
"outdoor_temperature": null,
"control_plan": {"generated_at": "2026-09-04T08:00:00Z", "zones": [], "rules": []},
"control_plan_revision": 42,
"system": {
"version": "0.14.12",
"uptime_seconds": 1234,
"auth_required": false,
"control_ready": true,
"database": "./data/gree-controller.db",
"device_count": 2,
"online_count": 2,
"simulator_count": 0,
"bind": "0.0.0.0:8787",
"base_path": "/",
"gree_interface": "auto",
"gree_received_frames": 809,
"gree_received_frames_by_device": {}
}
}
settings is a single startup snapshot composed from the same response models as the eight /api/settings/* GET endpoints. Secret values are never included; only *_configured flags are exposed for stored credentials. The split settings endpoints remain the canonical resources for independent reads and updates.
GET /api/system/info
Returns the system diagnostic object independently of the full bootstrap. Useful for monitoring and Settings → System status.
Device API
Device object
A device response contains:
| Field | Type | Description |
|---|---|---|
id |
string | Stable controller ID. |
mac |
string | Normalized GREE MAC/CID identity. |
name |
string | User-visible name. |
ip |
string | Device IPv4 address. |
port |
integer | Usually 7000. |
protocol_version |
integer | 0 unknown/auto, 1 legacy AES-ECB, 2 AES-GCM. |
model, firmware |
string | Discovered metadata when available. |
key |
string/null | GREE binding key. Treat as secret. |
cid |
string/null | GREE client/device identifier. |
enabled |
boolean | Technical device enable state. |
simulated |
boolean | Simulated vs physical. |
power |
boolean | Last known power. |
mode |
string | auto, cool, dry, fan, heat. |
target_temperature |
number | Last known unit setpoint. |
fan_speed |
integer | 0..5; 0 is Auto. |
swing_vertical, swing_horizontal |
boolean | Swing state. |
quiet, turbo, light, air, xfan, health, sleep |
boolean | Optional GREE features. |
supports_* |
boolean/null | Capability learned from device status. |
current_temperature |
number/null | GREE indoor temperature. |
outdoor_temperature |
number/null | GREE outdoor temperature if available. |
temperature_sensor_offset |
boolean/null | Whether +40 °C wire offset behavior was detected. |
online |
boolean | Current communication state. |
response_time_ms |
integer/null | Latest successful controller round-trip. |
last_seen |
ISO-8601/null | Last successful communication. |
last_error |
string/null | Latest communication error. |
communication_failures |
integer | Consecutive/recorded communication failure counter. |
created_at, updated_at |
ISO-8601 | Resource timestamps. |
POST /api/discovery
Request body, all fields optional:
{
"timeout_ms": 6000,
"broadcast": "255.255.255.255:7000",
"protocol_version": 0,
"passes": 3
}
Rules:
timeout_ms: effective range500..30000ms.protocol_version:0auto/both,1AES-ECB only,2AES-GCM only.passes:1..10.- Missing values use runtime GREE settings.
Successful discovery merges known devices, tries binding devices that do not have a key, persists results and returns:
{
"count": 1,
"devices": [],
"new_device_ids": ["gree-aabbccddeeff"]
}
GET /api/devices
Returns Device[].
POST /api/devices
Manual add request:
{
"name": "Living room",
"mac": "AABBCCDDEEFF",
"ip": "192.168.50.30",
"port": 7000,
"protocol_version": 1,
"key": null,
"simulated": false
}
Defaults: port=7000, protocol_version=1, simulated=false. MAC values are normalized. Duplicate MACs are rejected.
Returns 201 Created with Device.
GET /api/devices/{id}
Returns one Device or 404.
PATCH /api/devices/{id}
All fields optional:
{
"name": "Bedroom",
"ip": "192.168.50.31",
"port": 7000,
"protocol_version": 2,
"key": "optional-binding-key",
"enabled": true
}
key:null clears the key. Changing protocol version clears the existing key/capability cache so the unit can be re-bound cleanly. Disabling a device goes through the controller's safe disable path.
DELETE /api/devices/{id}
Returns 204. Deletion is rejected if the device is referenced by an automation or cannot be safely detached from thermostat ownership. Associated zones/groups are cleaned only after the safety checks pass.
POST /api/devices/{id}/bind
Performs/repeats GREE binding and returns updated Device. Simulated devices return unchanged.
POST /api/devices/{id}/probe
Performs a minimal, non-mutating GREE status round-trip and returns response_time_ms. It does not update device online/error counters, readings, capabilities, thermostat ownership, or persisted device state. A real device must already be bound.
{
"device_id": "gree-aabbccddeeff",
"response_time_ms": 18,
"ok": true
}
POST /api/devices/{id}/poll
Immediately polls one unit and returns updated Device.
POST /api/devices/{id}/command
Direct/manual device control. This is deliberately different from thermostat-zone control.
All fields optional; at least one meaningful field should be sent:
{
"power": true,
"mode": "cool",
"target_temperature": 22,
"fan_speed": 3,
"swing_vertical": true,
"swing_horizontal": false,
"quiet": false,
"turbo": false,
"light": true,
"air": false,
"xfan": false,
"health": false,
"sleep": false
}
Rules:
- modes:
auto,cool,dry,fan,heat, - target temperature is normalized to the supported GREE Celsius range
8..30, - fan speed is
0..5, - optional feature commands should be used only when the corresponding
supports_*capability is true.
The backend sends only properties that differ from the last known device state. Climate-relevant direct commands can create/continue a manual-device takeover for an enabled thermostat zone so automation does not immediately fight the user.
When the physical device belongs to a disabled thermostat zone, direct web/API control requires "manual_override": true. The web UI asks for explicit confirmation before sending that flag. Home Assistant direct-device control remains blocked for disabled zones.
Zones
Zone configuration
POST /api/zones and PUT /api/zones/{id} use this editable shape:
{
"name": "Living room",
"device_id": "gree-aabbccddeeff",
"enabled": true,
"mode": "cool",
"inherit_house_mode": true,
"setpoint": 23.0,
"cool_comfort_setpoint": 23.0,
"cool_sleep_setpoint": 24.5,
"cool_away_setpoint": 27.0,
"heat_comfort_setpoint": 21.0,
"heat_sleep_setpoint": 19.0,
"heat_away_setpoint": 17.0,
"hysteresis": 0.6,
"separate_hysteresis": false,
"cool_hysteresis": 0.6,
"heat_hysteresis": 0.6,
"min_on_seconds": 180,
"min_off_seconds": 180,
"min_adjust_seconds": 120,
"standby_offset_c": 2.0,
"smart_fan": true,
"sensor_source": "combined",
"ha_entity_id": "sensor.living_room_temperature",
"ha_outdoor_entity_id": "sensor.garden_temperature",
"external_sensor_weight": 0.4,
"max_sensor_difference": 3.0,
"sensor_stale_after_seconds": 300,
"revision": 12
}
Important rules:
nameis required.device_idmust reference an existing device and thermostat ownership must remain valid/safe.mode:coolorheatwhen not inheriting house mode.- temperature/profile values are constrained to the supported thermostat range.
hysteresis: shared controller hysteresis, valid range0.1..5.0°C.separate_hysteresis: whentrue, cooling usescool_hysteresisand heating usesheat_hysteresis; both use the same0.1..5.0°C range.standby_offset_c: bounded thermostat offset.sensor_source:device,home_assistantorcombined.- for
home_assistant/combined,ha_entity_idis the required Home Assistant room-temperature sensor for that zone. ha_outdoor_entity_idis optional; when empty, the zone uses global Home Assistantoutdoor_entity_id, and when set it overrides the outdoor-temperature source only for that zone. If the override is unavailable, the global outdoor source is used.external_sensor_weight:0..1.revisionis used for optimistic concurrency where supplied; stale updates can return409.
The returned Zone also contains runtime state including sensor readings, resolved/effective setpoints, demand, current preset, manual overrides, local Quick Thermostat ownership, temporary session state, device-manual takeover, control owner/source/reason, lockout timestamps and created_at/updated_at.
GET /api/zones
Returns Zone[].
POST /api/zones
Creates a zone and returns 201 Created with Zone.
GET /api/zones/{id}
Returns one Zone.
PUT /api/zones/{id}
Replaces editable zone configuration while preserving/reconciling runtime safety state. Returns updated Zone.
DELETE /api/zones/{id}
Safely powers the owned device off before detaching thermostat ownership. Returns 204.
POST /api/zones/{id}/control
Manual setpoint values are retained with 0.1 °C precision. The physical GREE unit setpoint is still rounded to the whole-degree resolution supported by the protocol.
Quick thermostat endpoint. Body fields are optional and can be combined:
{
"setpoint": 22.5,
"power": true,
"mode": "house",
"enabled": true,
"preset": "comfort",
"clear_override": false,
"clear_device_manual_override": false,
"clear_local_thermostat_override": false,
"temporary_quick_thermostat": null,
"clear_temporary_quick_thermostat": false
}
Semantics:
setpoint: creates a quick custom thermostat target.preset:auto,comfort,sleep,away,custom;autoclears the profile override.mode:house,cool,heat;houserestores global mode inheritance.enabled: zone automation enable state.power:true: local Quick Thermostat ownership — this zone can run through full thermostat logic regardless of whether group-level control is enabled for its climate group.power:false: turns this zone off and creates a fresh backend-owned local hand-back timer (currently 15 minutes).clear_local_thermostat_override:true: immediately return local Quick Thermostat ownership to normal automation. If there is no active schedule, manual preset/setpoint, Temporary Quick Thermostat or other explicit thermostat intent, the zone remains physically OFF instead of falling back to implicit Comfort.clear_device_manual_override:true: explicitly hand a physical/direct manual takeover back to the thermostat.clear_override:true: clear ordinary quick preset/setpoint override.temporary_quick_thermostat: start/replace a persisted temporary session.clear_temporary_quick_thermostat:true: cancel that temporary session only.
Returns updated Zone.
Temporary Quick Thermostat request
{
"start_kind": "now",
"start_delay_minutes": null,
"start_at": null,
"finish_kind": "duration",
"duration_minutes": 90,
"until": null,
"target_temperature": 23.0,
"temperature_operator": "within",
"tolerance_c": 0.3,
"hold_minutes": 60,
"max_duration_minutes": 240
}
start_kind:
nowdelay+start_delay_minutesat+ ISO-8601start_at
finish_kind:
duration+duration_minutesuntil+ ISO-8601untiltemperature_reachedtemperature_stable+hold_minutesschedule_boundary
Temperature operators:
withinat_or_belowat_or_above
max_duration_minutes is an optional fail-safe for temperature-based sessions. Delayed sessions do not own the zone until their effective start. Runtime session state is persisted and exposed inside the returned zone.
Examples:
# Preset until next schedule boundary
curl -X POST "$BASE/api/zones/ZONE_ID/control" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"preset":"sleep"}'
# Return to schedule
curl -X POST "$BASE/api/zones/ZONE_ID/control" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"preset":"auto"}'
# Run a 90-minute temporary thermostat at a decimal logical target
curl -X POST "$BASE/api/zones/ZONE_ID/control" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"temporary_quick_thermostat":{"start_kind":"now","finish_kind":"duration","duration_minutes":90,"target_temperature":24.2}}'
Temporary Quick Thermostat targets are normalized to 0.1 °C. The Web UI accepts both comma and dot decimal input (for example 24,2 and 24.2). Physical GREE device setpoint rounding is unchanged.
POST /api/zones/{id}/schedule-template
Body:
{
"template": "family"
}
Built-in templates:
| Template | Result |
|---|---|
family |
Comfort 06:30–22:30, Sleep overnight. |
child |
Comfort 06:30–20:30, Sleep overnight. |
bedroom |
Comfort 06:30–22:00, Sleep overnight. |
workday |
Weekday morning/away/evening/sleep plus weekend blocks. |
always |
24-hour Comfort. |
Existing schedules for the zone are replaced after overlap validation. Response:
{
"zone": {},
"schedules": []
}
Groups
Group object
{
"id": "uuid",
"name": "Bedrooms",
"zone_ids": ["zone-1", "zone-2"],
"power_enabled": true,
"created_at": "...",
"updated_at": "..."
}
GET /api/groups
Returns groups.
POST /api/groups
{
"name": "Bedrooms",
"zone_ids": ["zone-1", "zone-2"],
"power_enabled": true
}
A group must contain at least one existing zone. Returns 201 Created.
GET /api/groups/{id} / PUT /api/groups/{id} / DELETE /api/groups/{id}
Read, replace or delete a group. DELETE returns 204.
POST /api/groups/{id}/control
{
"power": true,
"mode": "house",
"preset": "custom",
"setpoint": 22.3
}
All fields optional:
power: enable/disable group-level control (legacy field name; this is not a device power gate),mode:house,cool,heat,preset:auto,comfort,sleep,away,custom,setpoint: custom group target in the8–30°Crange; requirespreset: "custom".
A custom setpoint creates the same override for every member zone. For explicit Web/Home Assistant group control it stays active until the group is changed/released; scheduled group automation remains bounded by the normal schedule hand-back. Returns a group control/result object including updated members/state.
Group power is a scoped bulk-power/control action. power=false immediately powers member units off and releases group:* ownership; members are stored as individually-off thermostats rather than being blocked by membership in an OFF group. This group-created OFF is indefinite (no 15-minute local hand-back), so the regulator cannot restart the unit by itself; a user can still turn an individual thermostat back on independently. power=true clears that scoped thermostat-OFF state and immediately re-runs group thermostat arbitration. Explicit Web/Home Assistant group control has higher priority than house rules and schedules; scheduled group automations still respect higher-priority manual/local ownership. Group mode/preset/setpoint changes are accepted only while the group is ON. Global ON/OFF never creates a persistent global gate. Global OFF does leave member thermostats locally OFF until they are explicitly re-enabled by local/group/global ON.
Whole-house control
House thermostat rules and global power actions are intentionally separate. Global ON/OFF does not create a master automation gate; OFF is persisted as per-zone local OFF so ordinary demand cannot immediately undo it.
POST /api/house/control
{
"mode": "cool"
}
Valid modes: cool, heat, off.
cool/heatselect the house rule used by zones that inherit the global mode and immediately re-run arbitration for free zones. Explicit local/group/direct ownership is preserved.offmeans do not perform house-level thermostat control for inherited free zones. It does not block local thermostats, groups, device-manual control or controller automations.
Returns { "mode": "cool|heat|off" }.
POST /api/house/power
{
"power": false
}
This endpoint is a bulk thermostat power action without a persistent blocking global gate. false first stores every thermostat as an indefinite local OFF and then sends immediate OFF to every technically enabled unit, so the next normal demand cycle cannot turn the house back on. A later per-zone Resume automation clears that local OFF but does not invent a Comfort demand: without an active schedule/override/temporary or another explicit intent the zone stays OFF. true is itself an explicit whole-house ON intent, releases local OFF markers for all thermostats and sends ON to all technically enabled units. Group enablement, profiles, schedules and house mode are preserved. Pending compressor-protection tasks from before the action are cleared. When compressor protection is enabled, protected global starts are queued until their safe deadline; OFF is never delayed.
Response includes:
{
"power": false,
"one_shot": true,
"devices": [],
"groups": [],
"failed": []
}
POST /api/house/preset
{
"preset": "sleep"
}
Valid: auto, comfort, sleep, away.
A non-auto preset creates overrides for free house-controlled zones and normally expires at each zone's next schedule boundary. auto clears those free-zone overrides. Explicit local thermostat, group, temporary thermostat and direct/manual ownership is not overwritten by a house profile action.
Response contains preset, the updated zones, current devices, and a failed array for immediate-control errors. It does not embed settings; settings are available only from the functional /api/settings/* resources.
Schedules
Schedule object/request:
{
"zone_id": "zone-1",
"name": "Night",
"enabled": true,
"weekdays": [1, 2, 3, 4, 5, 6, 7],
"start_time": "22:30",
"end_time": "06:30",
"preset": "sleep",
"setpoint": 24.5
}
Rules:
- weekdays use ISO numbers
1=Monday ... 7=Sunday, - times use local
HH:MM, - crossing midnight is supported,
start_time == end_timerepresents a 24-hour window for selected weekdays,- preset:
comfort,sleep,away,custom, - custom setpoint:
8..30°C, - enabled schedules for the same zone cannot overlap.
For non-custom presets, the effective target comes from the zone's seasonal profile; setpoint is retained for compatibility.
Routes:
GET /api/schedules
POST /api/schedules
GET /api/schedules/{id}
PUT /api/schedules/{id}
DELETE /api/schedules/{id}
Create returns 201; delete returns 204.
Automations
Automation request/object fields:
{
"name": "Hot room",
"enabled": true,
"trigger_kind": "temperature_above",
"trigger_device_id": "gree-aabbccddeeff",
"threshold": 27.0,
"at_time": null,
"action_device_id": "gree-aabbccddeeff",
"action_group_id": null,
"action_preset": null,
"action": {
"power": true,
"mode": "cool",
"target_temperature": 23
},
"cooldown_seconds": 300
}
Triggers:
temperature_above: requirestrigger_device_id+threshold,temperature_below: requirestrigger_device_id+threshold,time: requires localat_timeinHH:MM.
Action target is either:
- direct device:
action_device_id+ fullDeviceCommand, or - group:
action_group_id; group automation supports only power,house/cool/heatmode and optionalaction_preset(auto|comfort|sleep|away).
The response also contains runtime last_fired_at, created_at, updated_at.
Routes:
GET /api/automations
POST /api/automations
GET /api/automations/{id}
PUT /api/automations/{id}
DELETE /api/automations/{id}
Create returns 201; delete returns 204.
History and readings
GET /api/readings
Legacy/lightweight device history.
Query parameters:
| Parameter | Default | Description |
|---|---|---|
device_id |
all | Optional device filter. |
hours |
24 |
Clamped to 1..87600 (10 years). |
limit |
1500 |
Row limit. |
Response:
{
"readings": [
{
"id": 1,
"device_id": "gree-aabbccddeeff",
"timestamp": "...",
"indoor_temperature": 23.4,
"outdoor_temperature": 30.1,
"target_temperature": 23,
"power": true,
"source": "poll"
}
]
}
GET /api/history
Rich chart/history API.
Query parameters:
| Parameter | Description |
|---|---|
scope |
overview, zones/zone, devices, sensors; default zones. |
zone_id |
Zone filter for zone scope. |
device_id |
Device filter for device scope. |
entity_id |
Home Assistant entity filter for sensor scope. |
hours |
Default 24, clamped to 10 years. |
limit |
Default 12000, clamped to 1..20000. |
Bucket resolution:
| Range | Bucket |
|---|---|
| ≤ 6 h | 30 s |
| ≤ 24 h | 2 min |
| ≤ 7 d | 10 min |
| ≤ 30 d | 30 min |
| ≤ 90 d | 2 h |
| ≤ 1 y | 6 h |
| > 1 y | 24 h |
Zone reading fields:
id, zone_id, device_id, timestamp,
gree_temperature, external_temperature, control_temperature,
target_temperature, device_setpoint, outdoor_temperature,
power, mode, fan_speed, demand, control_source, active_preset
Device reading fields are the Reading fields documented above. HA sensor rows contain:
id, entity_id, zone_id, kind, timestamp, temperature
scope=overview returns all three families plus counts and per-family storage source.
When InfluxDB is enabled, older history can be read from Influx and merged with recent SQLite rows. A failed Influx query falls back to available SQLite data and reports storage_warning rather than failing the entire chart response.
Control plan
GET /api/control-plan
Returns the latest materialized machine-readable thermostat plan. The response shape is unchanged; the bundled Web UI receives plan updates primarily through WebSocket and uses this endpoint for fallback/resynchronization.
Top-level fields:
generated_at
house_mode
house_preset
house_power
outdoor_temperature
control_strategy
night_mode_active
night_mode_start
night_mode_end
night_mode_max_fan_speed
next_events[]
zones[]
rules[]
Each zone plan includes:
zone_id, zone_name, device_id, device_name,
enabled, effective_enabled,
mode, configured_mode, inherit_house_mode,
preset, preset_override,
current_temperature, target_temperature, device_setpoint,
desired_power, desired_mode,
actual_power, actual_mode, actual_setpoint,
demand, control_source,
manual_override_until,
local_thermostat_power, local_thermostat_resume_at,
device_manual_override, device_manual_override_until,
control_owner, control_command_source, control_since, resume_at, control_reason,
blocked_reason, lockout_until,
current_schedule_id, current_schedule_name,
next_events[]
This endpoint is the best way for another client to understand desired vs actual state, who owns control, and why a zone is blocked/paused.
Events and retention
GET /api/events?limit=100
Response:
{
"events": [
{
"id": 1,
"timestamp": "...",
"level": "info",
"kind": "device.updated",
"message": "...",
"metadata": {}
}
]
}
For events that are eligible for external notification, metadata.notification records the delivery result. status is sent, silent or failed. A silent event includes a reason such as alert_type_disabled, notifications_disabled, mode_filtered or cooldown; the Web UI shows these rows with a SILENT badge. Notification-status changes are also emitted as log.updated WebSocket events.
Runtime settings — 0.12.0
Version 0.12.0 replaces the monolithic settings document with functional resources. There are no compatibility aliases for the removed /api/settings, /api/debug or /api/events/retention endpoints.
Every settings resource supports GET and PUT. A PUT replaces only that functional section; it never requires or overwrites unrelated settings.
/api/settings/application
{
"simulator_enabled": false
}
/api/settings/gree
{
"controller_id": "gree-controller",
"poll_interval_seconds": 15,
"zone_interval_seconds": 5,
"discovery_timeout_ms": 3000,
"discovery_broadcast": "255.255.255.255:7000",
"suppress_device_beep": false,
"compressor_protection_enabled": true,
"compressor_protection_seconds": 180
}
Validation/normalization:
controller_idcannot be empty;- polling and zone intervals:
2..3600seconds; - discovery timeout:
300..30000ms; - discovery broadcast:
auto,auto:*or a socket address; - compressor protection:
30..1800seconds.
Changing compressor protection clears pending compressor runtime queues before thermostat control continues.
/api/settings/history
{
"retention_days": 30,
"compaction_enabled": true,
"event_retention_days": 30
}
Retention values are clamped to 1..3650 days. Updating this section immediately prunes expired event rows. The former /api/events/retention endpoint no longer exists.
/api/settings/influxdb
GET returns a secret-safe view:
{
"enabled": true,
"version": "2",
"url": "http://influxdb:8086",
"database": "gree_controller",
"username": "",
"password_configured": false,
"org": "home",
"bucket": "gree_controller",
"token_configured": true,
"history_threshold_days": 30
}
PUT uses the same non-secret fields plus optional password and token. Omitting either field (or sending null) preserves the stored secret. Sending an explicit empty string clears it. history_threshold_days is clamped to 1..3650; the complete InfluxDB configuration is validated before persistence.
/api/settings/notifications
GET returns provider state without secret values:
{
"enabled": true,
"mode": "problems",
"provider": "pushover",
"pushover_configured": true,
"slack_configured": false,
"discord_configured": false,
"cooldown_seconds": 300,
"communication_failure_threshold": 3,
"target_timeout_minutes": 60,
"alert_types": {
"stale_sensor": true,
"sensor_errors": true,
"communication": true,
"target_timeout": true,
"automation": true,
"sensor_discrepancy": true,
"control_errors": true,
"important_events": true,
"other": true
}
}
PUT accepts the same behavioral fields plus optional pushover_app_token, pushover_user_key, slack_webhook_url and discord_webhook_url. Omitted/null secrets are preserved; an explicit empty string clears them. Modes: problems, important. Providers: pushover, slack, discord. Cooldown is clamped to 30..86400 seconds, failure threshold to 2..100, target timeout to 5..1440 minutes. alert_types.sensor_discrepancy controls only notifications about GREE vs Home Assistant room-temperature divergence; the safety fallback to the GREE sensor remains active.
/api/settings/night
{
"enabled": false,
"start_time": "22:00",
"end_time": "06:00",
"max_fan_speed": 1,
"force_quiet": true,
"use_native_sleep": true
}
Times must use HH:MM; maximum fan speed is clamped to 1..5.
/api/settings/home-assistant
GET returns:
{
"url": "http://homeassistant.local:8123",
"auth_mode": "manual",
"token_configured": true,
"outdoor_entity_id": "sensor.outdoor_temperature",
"sensor_stale_after_seconds": 300,
"allow_invalid_tls": false,
"sensor_aliases": {
"sensor.room_temperature": "Living room"
},
"flow_inputs": [],
"outdoor_assist_enabled": true
}
auth_mode is runtime-only: manual for standalone installations and supervisor for the Home Assistant add-on. In Supervisor mode the returned URL is http://supervisor/core/, authentication uses runtime SUPERVISOR_TOKEN, and PUT does not replace the stored standalone URL/token fields. In manual mode, PUT replaces token_configured with optional token. Omitted/null token preserves the saved token; an explicit empty string clears it. outdoor_entity_id is the optional global Home Assistant outdoor-temperature sensor. Each zone can set ha_outdoor_entity_id to override that source only for the zone; a blank override uses the global sensor. Home Assistant room-temperature sensors remain configured per zone with ha_entity_id when sensor_source is home_assistant or combined. Sensor age is clamped to 30..86400 seconds. URLs, aliases, entity IDs and shared Flow inputs are normalized/validated before persistence. Global/per-zone outdoor sensors and per-zone room sensors are exposed through the normal alias and sensor-history/metric surfaces, and the Web UI offers them as suggestions in Flow Home Assistant entity fields. Shared inputs are value sources only; comparison operators and thresholds belong to Flow nodes. The Home Assistant connection test validates only the server/API token and requires no entity.
/api/settings/debug
{
"overlay_enabled": true,
"gree_frames": true
}
When overlay_enabled=true, live HTTP diagnostics can emit api.request; gree_frames=true enables sanitized gree.frame events.
Settings WebSocket events
Each section has its own event and payload:
settings.application.updated
settings.gree.updated
settings.history.updated
settings.influxdb.updated
settings.notifications.updated
settings.night.updated
settings.home_assistant.updated
settings.debug.updated
The generic settings.updated and debug.settings events were removed in 0.12.0.
Configuration backup and restore
GET /api/configuration/export
Returns configuration format version 3:
format_version
exported_at
settings
devices[]
zones[]
groups[]
schedules[]
automations[]
flows[]
The export contains GREE binding keys and integration credentials. It excludes metric history, event rows and generated API-token records. Treat it as a secret backup.
POST /api/configuration/import
Accepts only format version 3 and the setpoint control strategy used by 0.12.0. The backend validates IDs/references (including shared Flow inputs against resources inside the backup), Flow draft safety, schedules, settings and ownership relationships; safely powers off devices being detached; clears transient runtime/ownership state; replaces configuration; re-polls imported devices; then resumes thermostat control.
Metric/event history and generated access-token records are preserved.
Response:
{
"ok": true
}
Integration tests
POST /api/integrations/home-assistant/test
No request body is required. The endpoint validates the configured Home Assistant URL and access token against the Home Assistant API root; it does not read or require any entity. Response:
{
"ok": true
}
POST /api/integrations/home-assistant/entity
Reads the current raw Home Assistant entity document used by the shared-Flow-input diagnostics UI.
{
"entity_id": "climate.gas_boiler"
}
Response includes the raw state, availability, attributes and timestamps:
{
"ok": true,
"entity_id": "climate.gas_boiler",
"state": "heat",
"available": true,
"attributes": { "hvac_action": "heating" },
"last_changed": "2026-09-02T06:30:00Z",
"last_updated": "2026-09-02T06:30:05Z"
}
POST /api/integrations/notifications/test
Accepts a NotificationSettings object. Blank secret/webhook fields reuse saved secrets for the test.
Response:
{
"ok": true
}
Access tokens
GET /api/access-tokens
Returns:
[
{
"id": "uuid",
"name": "Home Assistant",
"token_prefix": "gree_controller_abc...",
"created_at": "..."
}
]
POST /api/access-tokens
{
"name": "Home Assistant"
}
Name length: 1..80. If omitted, default is Home Assistant.
Response 201 Created:
{
"token": "gree_controller_FULL_SECRET_SHOWN_ONCE",
"item": {
"id": "uuid",
"name": "Home Assistant",
"token_prefix": "gree_controller_...",
"created_at": "..."
}
}
DELETE /api/access-tokens/{id}
Revokes token and returns 204.
Restricted Home Assistant API
These routes always require a generated token or the administrator app token.
GET /api/integrations/home-assistant/devices
Returns Device[].
POST /api/integrations/home-assistant/devices/{id}/command
Accepts DeviceCommand. A direct command is rejected if the device belongs to a disabled thermostat zone; re-enable the zone for normal HA/controller ownership or use the administrator technical device endpoint deliberately.
GET /api/integrations/home-assistant/snapshot
Returns devices, groups, control_plan and control_plan_revision in one restricted request. The bundled Home Assistant coordinator uses this endpoint to reduce its normal refresh from three HTTP requests to one. The existing restricted devices/groups/control-plan endpoints remain available.
GET /api/integrations/home-assistant/control-plan
Same payload as administrator GET /api/control-plan.
GET /api/integrations/home-assistant/groups
Returns an HA-oriented derived group list. Each object includes:
id, name, zone_ids, zone_names,
power_enabled, effective_power,
mode, preset, house_mode,
zone_count, enabled_zones, active_zones, demanding_zones,
device_count, online_devices, current_temperature,
members[], next_events[]
Member rows include zone/device identity, configured/effective enable state, mode/preset, room/target temperature, demand, source, schedule and current manual/local ownership markers.
POST /api/integrations/home-assistant/groups/{id}/control
Same body/semantics as normal group control.
POST /api/integrations/home-assistant/house/control
Same { "mode": "cool|heat|off" } semantics as administrator house mode.
POST /api/integrations/home-assistant/house/preset
Same { "preset": "auto|comfort|sleep|away" } semantics.
POST /api/integrations/home-assistant/house/power
Same { "power": true|false } semantics.
POST /api/integrations/home-assistant/zones/{id}/control
Same ZoneControlPatch thermostat semantics as the normal zone control endpoint. The internal source is recorded as Home Assistant thermostat control.
WebSocket
Connection
Without administrator authentication:
ws://HOST:8787/ws
When GREE_CONTROLLER_APP_TOKEN is configured:
ws://HOST:8787/ws?token=APP_TOKEN
Generated restricted HA tokens are not WebSocket administrator tokens.
Message envelope
Every server event uses:
{
"event": "device.updated",
"timestamp": "2026-08-30T06:54:00Z",
"data": {}
}
The first frame is always bootstrap with the same payload as GET /api/bootstrap, including control_plan and control_plan_revision, unless bootstrap generation itself fails. If the generic event queue is overrun, the server sends another full bootstrap to resynchronize the client instead of silently continuing with missed state.
Common live events include:
bootstrap
control_plan.updated
device.created
device.updated
device.deleted
devices.discovered
zone.created
zone.updated
zone.deleted
group.created
group.updated
group.deleted
schedule.created
schedule.updated
schedule.deleted
schedule.template_applied
automation.created
automation.updated
automation.deleted
flow.created
flow.updated
flow.deleted
settings.application.updated
settings.gree.updated
settings.history.updated
settings.influxdb.updated
settings.notifications.updated
settings.night.updated
settings.home_assistant.updated
settings.debug.updated
house.mode_changed
outdoor.updated
configuration.imported
api.request
gree.frame_received
gree.frame
log.created
control_plan.updated uses data.revision plus data.plan. Revisions increase only when the materialized plan changes semantically; generated_at alone does not create a new revision.
zone.updated keeps the existing full-zone payload. Regulator passes that only advance the internal updated_at heartbeat are deduplicated and do not emit a frame; any actual zone state/sensor/control change still emits the full snapshot. Device polling keeps device.updated heartbeats for live last_seen UI, but heartbeat-only fields do not invalidate control-plan.
In 0.13.2, the bundled Web UI mirrors entity CRUD events directly into its local state. Schedule-template replacement performs a targeted schedule resync, configuration import performs a full bootstrap resync, and runtime automation/device-health changes publish their updated snapshots immediately.
In 0.13.3, logical thermostat targets use 0.1 °C precision consistently. Temporary Quick Thermostat accepts comma/dot decimal input in the bundled Web UI; hardware-specific GREE target rounding is unchanged.
In 0.13.4, disabled-zone thermostat controls remain visually active because explicit temporary/manual thermostat actions are still allowed while zone automation is disabled. The UI shows this distinction directly on the thermostat card; HTTP and WebSocket contracts are unchanged.
In 0.13.5, the same disabled-zone behavior is explained directly beside the zone enabled/disabled setting, so users see before changing it that disabling a zone stops automation but does not block manual thermostat, temporary thermostat or direct manual control. HTTP and WebSocket contracts remain unchanged.
In 0.13.6, notification settings add alert_types.sensor_discrepancy, allowing GREE vs Home Assistant temperature-difference notifications to be disabled independently from thermostat/group control errors. The sensor fallback behavior itself is unchanged.
In 0.13.7, the bootstrap payload also contains all eight redacted settings views. The bundled Web UI applies the same bootstrap mapper for initial HTTP load and WebSocket resynchronization, so a bootstrap frame no longer triggers eight additional settings GET requests.
Additional engine/integration events may be introduced without changing the envelope.
api.request data:
{
"method": "GET",
"path": "/api/system/info",
"status": 200,
"duration_ms": 2
}
GREE debug events are emitted only when enabled and are intended for diagnostics, not as a stable protocol API.
Localization endpoints
Language files are public so the UI can localize before administrator authentication.
GET /lang/index.json
Returns the generated catalog of embedded packs.
GET /lang/{code}.json
Returns one embedded language pack, e.g.:
GET /lang/en.json
GET /lang/pl.json
Practical API examples
Assume:
BASE='http://127.0.0.1:8787'
AUTH='Authorization: Bearer APP_TOKEN'
Discover devices:
curl -X POST "$BASE/api/discovery" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"protocol_version":0,"passes":3}'
Directly poll a device:
curl -X POST "$BASE/api/devices/DEVICE_ID/poll" -H "$AUTH"
Set a zone target:
curl -X POST "$BASE/api/zones/ZONE_ID/control" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"setpoint":22.5}'
Return zone to automatic scheduling:
curl -X POST "$BASE/api/zones/ZONE_ID/control" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"preset":"auto","clear_local_thermostat_override":true}'
Turn the whole managed house off:
curl -X POST "$BASE/api/house/power" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"power":false}'
Read current ownership/desired-vs-actual state:
curl "$BASE/api/control-plan" -H "$AUTH"
Read 90 days of zone history:
curl "$BASE/api/history?scope=zones&zone_id=ZONE_ID&hours=2160" -H "$AUTH"
Create a restricted Home Assistant token:
curl -X POST "$BASE/api/access-tokens" -H "$AUTH" -H 'Content-Type: application/json' \
-d '{"name":"Home Assistant"}'
Use that token:
curl -H 'Authorization: Bearer gree_controller_RESTRICTED_TOKEN' \
"$BASE/api/integrations/home-assistant/control-plan"
Visual Flow API
Flow is the source-of-truth representation for visual schedule/automation logic. GET /api/flows lists Flows; GET /api/flows/:id, POST /api/flows, PUT /api/flows/:id and DELETE /api/flows/:id manage them. A Flow payload contains name, enabled, optional draft, optional description, nodes and edges. draft=true is reserved for work-in-progress graphs: the backend forces them disabled and stores no generated schedules or automations.
Saving an executable Flow validates the DAG and compiles it atomically. If the editor receives HTTP 400 during normal save, it can offer to retry with draft=true; draft validation preserves the editable graph while allowing missing actions or unfinished semantic wiring. Drafts never execute, and converting an existing Flow to a draft atomically removes its previously generated outputs. A thermostat action driven only by one weekday block and one time-range block is emitted as a native schedule when its settings are schedule-compatible. More complex graphs are emitted as Flow-triggered automations. Generated schedules and automations expose flow_id / flow_node_id, use stable names in the form flow-<stable-unique-id>, and cannot be edited or deleted through their legacy endpoints; edit the owning Flow instead.
Condition blocks support weekday, time/date ranges, optional 5-field CRON, application Night mode, outdoor/device/zone temperatures, house/device/zone/group state, arbitrary Home Assistant state/numeric/attribute/availability sources, rolling mean/median, oscillation detection, and shared_input references. Stateful gate blocks include stable_for, delay, state_duration (min_seconds, optional max_seconds), on_change (mode: result|value) and rate_limit (max_count, period_seconds). on_change establishes a baseline on its first observation and does not fire immediately. rate_limit must feed an action directly and consumes quota only after a successful action execution. Shared inputs are stored in home_assistant.flow_inputs and resolve dynamically at evaluation time. Shared inputs store reusable value sources only. They never store a comparison operator or threshold. For comparison-capable source kinds, each shared_input Flow node defines its own operator and value. PUT /api/settings/home-assistant rejects shared-input configs that contain an operator, and rejects comparison value fields for comparison-capable source kinds. Logic blocks support AND, OR and NOT. Action blocks target thermostat zones, GREE devices, climate groups or a generic Home Assistant service. Direct GREE actions map to the existing DeviceCommand fields including fan, swing, quiet, turbo, light, air, xfan, health and sleep; ownership rules may suppress fields that would fight an active thermostat. Flow group actions use the existing group controller and support power, house/heat/cool mode, auto/comfort/sleep/away and the existing custom group target.
Compressor protection queue
Runtime settings expose compressor_protection_enabled and compressor_protection_seconds (30–1800; default 180). While enabled, thermostat starts and Heat/Cool reversals that fall inside the protection window are represented on the owning zone by compressor_pending_action, compressor_pending_since, and compressor_pending_until.
POST /api/zones/:id/compressor-queue/cancelcancels the currently pending compressor-protection task for one thermostat.POST /api/compressor-queue/cancel-allcancels all currently pending compressor-protection tasks.
Cancellation suppresses the same pending intent until a new explicit thermostat/group/house command re-arms it, a scheduled Temporary Quick Thermostat session takes ownership, or a different mode/target creates a new intent. Safety OFF commands are not delayed by compressor protection. Direct technical device commands remain immediate manual-control operations.
Flow portability and diagnostics
GET /api/flows/:id/export returns a versioned gree-controller-flow JSON document containing only the source graph. Generated schedules/automations are not exported.
POST /api/flows/import accepts either that envelope or a direct Flow source payload, creates a new Flow ID/revision, and preserves draft state. Executable imports are validated and recompiled; draft imports remain disabled with no generated outputs.
POST /api/flows/simulate accepts { flow, flow_id?, at?, overrides?, log? }. at is RFC3339. overrides maps Flow node IDs to simulated values. The endpoint validates and compiles the graph, evaluates every action and returns per-node traces plus matched, would_execute and blocked_reason (for example disabled zone/device, manual/local/temporary thermostat ownership, thermostat-output conflict or disabled Flow). It never mutates thermostat/device/group/schedule/automation state. Home Assistant read/attribute/parse failures evaluate safely as false and are visible in the trace instead of accidentally satisfying NOT/neq logic.
GET /api/flows/:id/logs?limit=100 returns events associated with the Flow or its generated automations.
Existing Flow updates require expected_revision. A mismatched revision returns HTTP 409 to prevent stale editor tabs from overwriting newer graphs. Source Flow plus generated outputs are replaced atomically in one database transaction while configuration/automation/schedule/thermostat-cycle operations are serialized.
Additional Flow condition blocks are house_mode, device_state, zone_state, group_state, night_mode, ha_attribute, ha_available, constant and shared_input, alongside weekday/time/date, temperature, Home Assistant state/numeric and AND/OR/NOT blocks. device_state can inspect enabled/online/power/mode/fan/swing/quiet/turbo/light/air/xfan/health/sleep state. The editor ships 37 categorized editable templates covering comfort, energy, safety, night, reliability, Home Assistant heat-source coordination and advanced multi-branch logic. The template UI adds search, favorites/recent history, a graph preview and runtime requirement checks; shared inputs expose usage links and HA-backed inputs can be tested against live entity state.
Swing control across manual, thermostat and automation surfaces — 0.14.2
Local device control exposes vertical (swing_vertical) and horizontal (swing_horizontal) swing independently. Thermostat zone UI and the bundled Home Assistant zone climate entity expose the same auxiliary controls when the assigned device reports support; changing swing does not hand thermostat ownership to manual control.
Legacy direct-device automations accept optional swing_vertical and swing_horizontal action fields. Visual Flow exposes both axes in device_action and zone_thermostat actions and in device-state conditions. A zone_thermostat Flow using swing compiles to an automation rather than a native schedule so the auxiliary command is preserved. Swing remains outside the thermostat's continuously regulated fan/temperature outputs.
Split/multisplit installations and energy comparison — 0.14.1
Installation configuration endpoints:
GET|POST /api/device-groupsGET|PUT|DELETE /api/device-groups/{id}
A device group represents one physical split or multisplit installation. It contains one or more indoor device_ids, an optional shared GREE Cloud energy device or Home Assistant cumulative-energy entity, and an optional member device used as the shared outdoor-temperature source. One device may belong to only one installation.
Energy history accepts either a device ID or group:<installation-id> as a target. The Web UI can request several targets in parallel and overlay them on one chart. compare=previous_day|previous_period|previous_year shifts the requested range for period comparison; compare=none disables comparison. Daily buckets are presented as calendar dates.
When the final registered GREE Cloud device is removed, the controller closes the unused MQTT session. MQTT messages already in flight after removal are ignored while no Cloud devices are registered, preventing repeated stale-device warnings.
GREE Cloud and energy — 0.14.0
Devices now expose connection_type, connection_status, capabilities, Cloud synchronization fields and energy-source metadata through the existing device API. Local and Cloud devices use the same command endpoint; dispatch is selected strictly by connection_type.
Cloud account/discovery/diagnostic endpoints:
GET|PUT /api/settings/gree-cloudPOST /api/integrations/gree-cloud/testGET /api/integrations/gree-cloud/devicesPOST /api/integrations/gree-cloud/devices/{cloud_id}/addGET /api/integrations/gree-cloud/statusPOST /api/integrations/gree-cloud/reconnectGET /api/devices/{id}/cloud-diagnostics
Energy endpoints:
GET /api/integrations/home-assistant/energy-sensorslists compatible cumulative HA energy sensors. If Home Assistant is not configured, it returns200withconfigured: falseand an emptysensorsarray; configured dependency failures use HTTP424.GET /api/history/energy?device_id=...&interval=hourly|daily|weekly|monthly&source=auto|gree_cloud|home_assistantreturns consumption buckets and period summaries in kWh.
Cloud settings and diagnostics are redacted: passwords, REST/MQTT tokens, Authorization values and device cipher keys are not returned.
Connectivity history — 0.14.2
GET /api/history/network?hours=24&target_id=all returns connectivity batches for Local/LAN units and, when enabled, controller-level cloud:rest and cloud:mqtt endpoints. Each reading contains latency_ms, jitter_ms, packet_loss_pct, sample_count, successful_samples, target_kind and source.
Local connectivity sampling is configured through GET/PUT /api/settings/gree using ping_metrics_enabled, ping_interval_seconds and ping_sample_count. Direct unit probes are Local/LAN-only. GREE Cloud connectivity sampling is configured through GET/PUT /api/settings/gree-cloud using connectivity_metrics_enabled, connectivity_metrics_interval_seconds and connectivity_metrics_sample_count; it is disabled by default and measures REST login response plus MQTT PINGRESP round-trip. Connectivity history follows the same SQLite retention/compaction and optional InfluxDB archive policy as other history metrics.